Ultrasound biomicroscopy findings of 25 G Transconjuctival sutureless (TSV) and conventional (20G) pars plana sclerotomy in the same patient
Open Access
- 28 February 2006
- journal article
- case report
- Published by Springer Nature in BMC Ophthalmology
- Vol. 6 (1) , 7
- https://doi.org/10.1186/1471-2415-6-7
Abstract
Background Transconjunctival Sutureless Vitrectomy (TSV) is a recent advancement in vitreo-retinal surgical techniques involving the use of 25 G instruments through self-sealing sclerotomies. It has been hypothesized that there may be less chance of vitreous and retinal herniation in the scleral wound as compared to conventional sclerotomy incision. However there are no reports on differences in 20 gauge and 25 gauge sclerotomies using ultrasound biomicroscopy (UBM). We report herein the differences in sclerotomies undertaken with 20 gauge (G) and 25 gauge instruments in the same patient. Case presentation Ultrasound biomicroscopy of the sclerotomy sites was done in the same patient in whom both 20 G and 25 G sclerotomies had to be constructed during pars plana vitrectomy and the differences were studied. On day 2, we observed a wide gape at the site that had been enlarged using a 20G MVR blade. In contrast, the other two sites made transconjunctivally using the 25G trocar showed only a mild gape. Significant gape continued to persist at the subsequent evaluations on day 7 and day 14 only at the port, which had been enlarged. Conclusion Healing of a 25 G sclerotomy is expectedly quite rapid, with inability to detect the site of sclerotomy in a short duration of 2 weeks post-operatively. This is as opposed to conventional sclerotomies, which might take up to 6–8 weeks post-operatively for complete opposition.Keywords
This publication has 7 references indexed in Scilit:
- Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch & Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Ultrasound biomicroscopy of conventional and sutureless pars plana sclerotomies: a comparative and longitudinal studyAmerican Journal of Ophthalmology, 2001
- Ultrasound biomicroscopy of sclerotomy sites after pars plana vitrectomy for diabetic vitreous hemorrhage11The authors have no proprietary interest in any of the materials used in this study.Ophthalmology, 2000
- Ultrasound biomicroscopic analysis of anterior proliferative vitreoretinopathyAmerican Journal of Ophthalmology, 1998
- Ultrasound Biomicroscopy in the Diagnosis of Persistent Hypotony After VitrectomyAmerican Journal of Ophthalmology, 1997
- Ultrasound Biomicroscopy for Examination of the Sclerotomy Site After Pars Plana VitrectomyAmerican Journal of Ophthalmology, 1994
- Vitreous SurgeryArchives of Ophthalmology (1950), 1977