Diagnostic Accuracy of Real-time Polymerase Chain Reaction in Detection of Clostridium difficile in the Stool Samples of Patients With Suspected Clostridium difficile Infection: A Meta-Analysis
Open Access
- 1 October 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Infectious Diseases
- Vol. 53 (7) , e81-e90
- https://doi.org/10.1093/cid/cir505
Abstract
Background. Current detection methods for Clostridium difficile infection (CDI) can be time-consuming and have variable sensitivities. Real-time polymerase chain reaction (PCR) may allow earlier and more accurate diagnosis of CDI than other currently available diagnostic tests. A meta-analysis was performed to determine the diagnostic accuracy of real-time PCR. Methods. We searched MEDLINE (Pubmed/Ovid) and 4 other online electronic databases (1995–2010) to identify diagnostic accuracy studies that compared PCR with cell culture cytotoxicity neutralization assay (CCCNA) or anaerobic toxigenic culture (TC) of C. difficile. Screening for inclusion, data extraction, and quality assessment were carried out independently by 2 investigators and disagreements resolved. Data were combined by means of a random-effects model, and summary receiver operating characteristic curves and diagnostic odds ratios were calculated. Results. Nineteen studies (7392 samples) met our inclusion criteria. The overall mean sensitivity of PCR was 90% (95% confidence interval [CI]: 88%–91%), specificity 96% (CI: 96%–97%), positive likelihood ratio 26.89 (CI: 20.81–34.74), negative likelihood ratio 0.11 (CI: .08–.15), diagnostic odds ratio 278.23 (CI: 213.56–362.50), and area under the curve 0.98 (CI: .98–.99). Test accuracy depended on the prevalence of C. difficile but not on the reference test used. At C. difficile prevalence of 20% the positive predictive value and the negative predictive value were 71%, 79%, 93% and 99%, 98% and 96%, respectively. Conclusions. Real-time PCR has a high sensitivity and specificity to confirm CDI. Overall diagnostic accuracy is variable and depends on CDI prevalence.Keywords
This publication has 38 references indexed in Scilit:
- Clostridium difficile Testing in the Clinical Laboratory by Use of Multiple Testing AlgorithmsJournal of Clinical Microbiology, 2010
- Evaluation of a New Commercial TaqMan PCR Assay for Direct Detection of the Clostridium difficile Toxin B Gene in Clinical Stool SpecimensJournal of Clinical Microbiology, 2009
- Comparison of a Rapid Molecular Method, the BD GeneOhm Cdiff Assay, to the Most Frequently Used Laboratory Tests for Detection of Toxin-Producing Clostridium difficile in Diarrheal FecesJournal of Clinical Microbiology, 2009
- Comparison of Nine Commercially Available Clostridium difficile Toxin Detection Assays, a Real-Time PCR Assay for C . difficile tcdB , and a Glutamate Dehydrogenase Detection Assay to Cytotoxin Testing and Cytotoxigenic Culture MethodsJournal of Clinical Microbiology, 2009
- Rapid Detection of Toxigenic Strains of Clostridium difficile in Diarrheal Stools by Real-Time PCRJournal of Clinical Microbiology, 2009
- Comparison of a Commercial Real-Time PCR Assay for tcdB Detection to a Cell Culture Cytotoxicity Assay and Toxigenic Culture for Direct Detection of Toxin-Producing Clostridium difficile in Clinical SamplesJournal of Clinical Microbiology, 2009
- Comparison of Three Commercial Methods for Rapid Detection of Clostridium difficile Toxins A and B from Fecal SpecimensJournal of Clinical Microbiology, 2008
- Comparison of Real-Time PCR for Detection of the tcdC Gene with Four Toxin Immunoassays and Culture in Diagnosis of Clostridium difficile InfectionJournal of Clinical Microbiology, 2008
- Meta-analysis in clinical trialsControlled Clinical Trials, 1986