Effects of heart rate on ventricular size, stroke volume, and output in the normal human fetus: a prospective Doppler echocardiographic study.
- 1 July 1987
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 76 (1) , 52-58
- https://doi.org/10.1161/01.cir.76.1.52
Abstract
The effect of heart rate on cardiac output in the fetal heart is controversial. We used Doppler echocardiography to investigate the effects of increasing heart rate on stroke volume and ventricular output in the normal human fetal heart. Heart rate was increased in 25 human fetuses (mean age 36 weeks) by auditory stimulation with a sound emitter placed on the mother's abdomen. Aortic or pulmonary diameters were measured at valve level from two-dimensional echocardiographic images and cross-sectional areas were calculated. Blood flow velocity spectra from the pulmonary artery or aorta were digitized to obtain flow velocity integrals before and after auditory stimulation. Stroke volume was calculated as the product of the flow velocity integral and the area of the great vessel. Prestimulation mean heart rate was 132 +/- 8 beats/min and increased after auditory stimulation to 158 +/- 9 beats/min (p less than .001). Stroke volume decreased with the increase in heart rate from 3.7 +/- 1.4 ml before stimulation to 3.0 +/- 1.1 ml after stimulation (p less than .001), but ventricular output calculated as the product of stroke volume and heart rate remained unchanged (0.48 +/- 0.18 liter/min before vs 0.48 +/- 0.17 liter/min after stimulation). The decrease in stroke volume was accompanied by a decrease in ventricular end-diastolic area, although there was no change either in end-systolic area or fractional change in area. This study demonstrates that increases in heart rate within the physiologic range in the normal human fetus result in a decrease in ventricular size and stroke volume but no change in ventricular output or ventricular shortening.This publication has 25 references indexed in Scilit:
- Maturational changes in myocardial pump performance in newborn lambsAmerican Heart Journal, 1986
- Variable effects of changes in flow rate through the aortic, pulmonary and mitral valves on valve area and flow velocity: Impact on quantitative doppler flow calculationsJournal of the American College of Cardiology, 1985
- Fetal doppler echocardiography: Methods and characterization of normal and abnormal hemodynamicsThe American Journal of Cardiology, 1984
- Determination of cardiac output by Doppler echocardiography.Heart, 1984
- The Development of Human Fetal HearingScience, 1983
- Fetal echocardiographyThe American Journal of Cardiology, 1983
- Left ventricular end-systolic stress-shortening and stress-length relations in humansThe American Journal of Cardiology, 1982
- Response of the left ventricle to stress: Effects of exercise, atrial pacing, afterload stress and drugsThe American Journal of Cardiology, 1981
- Fetal and Neonatal Circulation and RespirationAnnual Review of Physiology, 1974
- The intrinsic physiologic properties of the developing heartProgress in Cardiovascular Diseases, 1972