Detection of Human Polyomaviruses in Urine from Bone Marrow Transplant Patients: Comparison of Electron Microscopy with PCR
Open Access
- 1 February 2004
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 50 (2) , 306-312
- https://doi.org/10.1373/clinchem.2003.024539
Abstract
Background: We studied electron microscopy (EM) as an appropriate test system for the detection of polyomavirus in urine samples from bone marrow transplant patients. Methods: We evaluated direct EM, ultracentrifugation (UC) before EM, and solid-phase immuno-EM (SPIEM). The diagnostic accuracy of EM was studied by comparison with a real-time PCR assay on 531 clinical samples. Results: The detection rate of EM was increased by UC and SPIEM. On 531 clinical urine samples, the diagnostic sensitivity of EM was 47% (70 of 149) with a specificity of 100%. We observed a linear relationship between viral genome concentration and the proportion of urine samples positive by EM, with a 50% probability for a positive EM result for urine samples with a polyomavirus concentration of 106 genome-equivalents (GE)/mL; the probability of a positive EM result was 0% for urine samples with <103 GE/mL and 100% for urine samples containing 109 GE/mL. Conclusions: UC/EM is rapid and highly specific for polyomavirus in urine. Unlike real-time PCR, EM has low sensitivity and cannot quantify the viral load.Keywords
This publication has 14 references indexed in Scilit:
- Utility of urinary cytology for diagnosing human polyoma virus infection in transplant recipients: a study of 37 cases with electron microscopic analysis.Diagnostic Cytopathology, 2001
- Diagnostic virology — the need for electron microscopy: a discussion paperJournal of Clinical Virology, 2001
- Rationalised virological electron microscope specimen testing policyJournal of Clinical Pathology, 2000
- Treatment of BK virus-associated hemorrhagic cystitis and simultaneous CMV reactivation with cidofovirBone Marrow Transplantation, 2000
- Rationalised virological electron microscope specimen testing policyJournal of Clinical Pathology, 2000
- Diagnostic electron microscopy is still a timely and rewarding methodJournal of Clinical Virology, 1999
- A rationalised virological electron microscope specimen testing policy. PHLS North West Viral Gastroenteritis and Electron Microscopy SubcommitteeJournal of Clinical Pathology, 1999
- Morphologic Identification of Viral Gastroenteritis Caused by a Human Calicivirus Strain Undetected Initially by Molecular or Immunologic MethodsMicroscopy and Microanalysis, 1997
- Association between polyomaviruria and microscopic haematuria in bone marrow transplant recipientsJournal of Infection, 1994
- HEMORRHAGIC CYSTITIS AFTER BONE MARROW TRANSPLANTATION RISK FACTORS AND COMPLICATIONSTransplantation, 1993