Spot size and quality of scanning laser correction of higher-order wavefront aberrations
- 1 March 2002
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 28 (3) , 407-416
- https://doi.org/10.1016/s0886-3350(01)01163-4
Abstract
To investigate the effect of laser spot size on the outcome of aberration correction with scanning laser corneal ablation. Cleveland Clinic Foundation, Cleveland, Ohio, USA. Corrections of wavefront aberrations of Zernike modes from the second to eighth order were simulated. Gaussian and top-hat beams of 0.6 to 2.0 mm full-width-half-maximum diameters were modeled. The fractional correction and secondary aberration (distortion) were evaluated. Using a distortion/correction ratio of less than 0.5 as a cutoff for adequate performance, a 2.0 mm or smaller beam was adequate for spherocylindrical correction (Zernike second order), a 1.0 mm or smaller beam was adequate for correction of up to fourth-order Zernike modes, and a 0.6 mm or smaller beam was adequate for correction of up to sixth-order Zernike modes. Since ocular aberrations above the Zernike fourth order are relatively insignificant in normal eyes, current scanning lasers with a beam diameter of 1.0 mm or less are theoretically capable of eliminating most higher-order aberrations.Keywords
This publication has 24 references indexed in Scilit:
- Clinical results of wavefront-guided laser in situ keratomileusis 3 months after surgeryJournal of Cataract & Refractive Surgery, 2001
- Early clinical experience using custom excimer laser ablations to treat irregular astigmatismJournal of Cataract & Refractive Surgery, 2000
- Topography-driven photorefractive keratectomy Results of corneal interactive programmed topographic ablation softwareOphthalmology, 2000
- Topographically-guided laser in situ keratomileusis to treat corneal irregularitiesOphthalmology, 2000
- Selective zonal ablations with excimer laser for correction of irregular astigmatism induced by refractive surgeryOphthalmology, 2000
- Supernormal vision, hypervision, and customized corneal ablationJournal of Cataract & Refractive Surgery, 2000
- Laser in situ keratomileusis assisted by corneal topographyJournal of Cataract & Refractive Surgery, 1998
- Supernormal vision and high-resolution retinal imaging through adaptive opticsJournal of the Optical Society of America A, 1997
- The physics of UV laser cornea ablationIEEE Journal of Quantum Electronics, 1991
- Quantitation of Corneal Ablation by Ultraviolet Laser LightArchives of Ophthalmology (1950), 1985