In orthodontic treatment malpositions of teeth are often corrected by fixed appliances, consisting, in part, of loops made by the orthodontist. The most important alloys in use are steel, cobalt-chromium, or titanium-molybdenium alloys. The static force systems of fixed appliances made of these materials are well known from experimental and numerical studies, but as they may change during tooth movement, we are often confronted with problems in therapy. The introduction of pseudoelastic nickel titanium alloys (NiTi) into orthodontic treatment, offers the chance of improving the effectiveness and reliability of orthodontic devices. In the present paper a plane finite element (FE) for the analysis of orthodontic loops is presented. It enables the determination of the nonlinear behaviour of pseudoelastic NiTi-alloys and is capable of simulating large structural displacements and rotations accompanied by moderate strains. A comparative numerical and experimental study shows the efficiency of this element. The associated results reflect pseudoelastic effects on certain loop designs, and reveal the benefits for the orthodontist and his patients.Keywords
This publication has 14 references indexed in Scilit:
- Materialtechnische Besonderheiten orthodontischer Nickel-Titan-DrähteJournal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 1990
- Large Deformation Analysis of Orthodontic AppliancesJournal of Biomechanical Engineering, 1990
- Geometric and material parameters of a nickel-titanium and a beta titanium orthodontic arch wire alloyDental Materials, 1987
- Force Generation From Orthodontic AppliancesJournal of Biomechanical Engineering, 1982
- Force Systems from Orthodontic Appliances: An Analytical and Experimental ComparisonJournal of Biomechanical Engineering, 1980
- A clinical trial of alignment of teeth using a 0.019 inch thermal nitinol wire with a transition temperature range between 31 °C. and 45 °C.American Journal of Orthodontics, 1980
- Three-dimensional large displacement analysis of orthodontic appliancesJournal of Biomechanics, 1976
- Force systems from an ideal archAmerican Journal of Orthodontics, 1974
- An Evaluation of 55 Cobalt Substituted Nitinol Wire for Use in OrthodonticsThe Journal of the American Dental Association, 1971
- Effect of Low-Temperature Phase Changes on the Mechanical Properties of Alloys near Composition TiNiJournal of Applied Physics, 1963