Effect of optical property estimation accuracy on tomographic bioluminescence imaging: simulation of a combined optical–PET (OPET) system
- 3 April 2006
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (8) , 2045-2053
- https://doi.org/10.1088/0031-9155/51/8/006
Abstract
Inevitable discrepancies between the mouse tissue optical properties assumed by an experimenter and the actual physiological values may affect the tomographic localization of bioluminescent sources. In a previous work, the simplifying assumption of optically homogeneous tissues led to inaccurate localization of deep sources. Improved results may be obtained if a mouse anatomical map is provided by a high-resolution imaging modality and optical properties are assigned to segmented tissues. In this work, the feasibility of this approach was explored by simulating the effect of different magnitude optical property errors on the image formation process of a combined optical-PET system. Some comparisons were made with corresponding simulations using higher spatial resolution data that are typically attainable by CCD cameras. In addition, simulation results provided insights on some of the experimental conditions that could lead to poor localization of bioluminescent sources. They also provided a rough guide on how accurately tissue optical properties need to be known in order to achieve correct localization of point sources with increasing tissue depth under low background noise conditions.Keywords
This publication has 13 references indexed in Scilit:
- Spectrally resolved bioluminescence optical tomographyOptics Letters, 2006
- Investigation of OPET performance using GATE, a Geant4-based Simulation softwareIEEE Transactions on Nuclear Science, 2004
- Detector concept for OPET-a combined PET and optical imaging systemIEEE Transactions on Nuclear Science, 2004
- Development of a 4-D digital mouse phantom for molecular imaging researchMolecular Imaging & Biology, 2004
- Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal ModelsMolecular Imaging, 2004
- Fundamental image quality limits for microcomputed tomography in small animalsMedical Physics, 2003
- Molecular imaging of small animals with dedicated PET tomographsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002
- In vivo imaging of light-emitting probesJournal of Biomedical Optics, 2001
- A finite element approach for modeling photon transport in tissueMedical Physics, 1993
- The convergence of object dependent resolution in maximum likelihood based tomographic image reconstructionPhysics in Medicine & Biology, 1993