Studies on Mechanical Strength of Bone: II.Torsional Strength of Cortical Bone after Rigid Plate Fixation with and without Compression
- 1 January 1978
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 49 (6) , 506-511
- https://doi.org/10.3109/17453677808993230
Abstract
Biomechanical properties of intact rabbit tibio-fibulae were investigated with torsional loading 1 day to 36 weeks alter fixation using 4-hole stainless steel ASIF/DCP plates with and without compression. During the first 12 weeks energy absorption and torque moment increased slightly as a result of subperiosteal new bone formation following application of the plates. There was a concomitant increase in the yielding properties of the bone, reflecting progressive porotic transformation. Thereafter, up to 36 weeks postoperatively, the values for energy absorption, torque moment and angular deformation gradually declined in both groups of bones. The differences between normal control bones and plated bones at 36 weeks were 70.1, 53.0 and 26.3 per cent, respectively. The decay of torsional strength was the same whether or not compression was used in the plate fixation. The results suggest that even in normal bone rigid plates induce a considerable loss of strength due to the cancellous transformation they are known to cause in cortical bone.Keywords
This publication has 14 references indexed in Scilit:
- Structural changes in intact tubular bone after application of rigid plates with and without compression.Journal of Bone and Joint Surgery, 1978
- Studies on Mechanical Strength of Bone:I. Torsional Strength of Normal Rabbit Tibio-Fibular BoneActa Orthopaedica, 1978
- A comparison of cortical bone atrophy secondary to fixation with plates with large differences in bending stiffnessJournal of Bone and Joint Surgery, 1976
- Quantitative histological evaluation of early fracture healing of cortical bones immobilized by stainless steel and composite platesCalcified Tissue International, 1975
- Histologische und histomorphometrische Veränderungen bei Plattenosteosynthesen nach Osteotomien an der Tibia des KaninchensArchives of orthopaedic and trauma surgery, 1975
- Experiments for the determination of calcium density in osteotomized and stabilised rabbit tibiaeArchives of orthopaedic and trauma surgery, 1975
- Tibial fractures treated according to the AO methodInjury, 1973
- Refrakturen und neue Frakturen der Tibia nach AO-Platten- und Schrauben-OsteosynthesenArchives of orthopaedic and trauma surgery, 1973
- Bone StrengthJournal of Bone and Joint Surgery, 1972
- Bone Structure Changes in the Dog Under Rigid Internal FixationClinical Orthopaedics and Related Research, 1971