The Effect of Methodological Differences in the Measurement of Stapes Motion in Live and Cadaver Ears
Open Access
- 1 April 2006
- journal article
- research article
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 11 (3) , 183-197
- https://doi.org/10.1159/000091815
Abstract
Methodological differences in sound-induced stapes velocity (Vs) measurements in live and cadaveric ears were examined using fresh cadaveric temporal bones. On average, differences in preparation (sectioning the stapedius tendon, removing the facial nerve, and widely opening the facial recess) had statistically insignificant effects on measured Vs. Differences in the achievable measurement angle (with respect to the axis of piston-like stapes motion) had a significant effect on measured Vs below 2 kHz. These results suggest that much if not all of the differences in Vs measurements between live and cadaveric ears can be explained by the differences in measurement angle between the two preparations. Measurement angle was found to have minimal effect on measured Vs above 2 kHz. This demonstrates that the commonly used method of estimating stapes translational velocity by dividing the measured velocity by the cosine of the measurement angle is not valid above 2 kHz.Keywords
This publication has 18 references indexed in Scilit:
- Experimental and Clinical Studies of Malleus FixationThe Laryngoscope, 2005
- Mechanisms of hearing loss resulting from middle-ear fluidHearing Research, 2004
- MEASUREMENT, VISUALIZATION AND QUANTITATIVE ANALYSIS OF COMPLETE THREE-DIMENSIONAL KINEMATICAL DATA SETS OF HUMAN AND CAT MIDDLE EARPublished by World Scientific Pub Co Pte Ltd ,2004
- Three-Dimensional Stapes Footplate Motion in Human Temporal BonesAudiology and Neurotology, 2003
- Middle-ear transmission in humans: wide-band, not frequency-tuned?Acoustics Research Letters Online, 2003
- Analysis of the Best Site on the Stapes Footplate for Ossicular Chain ReconstructionActa Oto-Laryngologica, 1999
- Inverted follicular keratosisAmerican Journal of Otolaryngology, 1993
- Cadaver Middle Ears as Models for Living Ears: Comparisons of Middle Ear Input ImmittanceAnnals of Otology, Rhinology & Laryngology, 1990
- Measurement of the Ossicular Vibration Ratio in Human Temporal Bones by Use of a Video Measuring SystemActa Oto-Laryngologica, 1987
- Temporal Bone Removal at Autopsy: Preparation and UsesJAMA Otolaryngology–Head & Neck Surgery, 1968