Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature
- 1 January 1998
- journal article
- review article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 43 (2) , 192-203
- https://doi.org/10.1002/(sici)1097-4636(199822)43:2<192::aid-jbm14>3.0.co;2-k
Abstract
A significant no‐load healing period is the generally accepted prerequisite for osseointegration in dental implantology. The aim of this article was to examine whether this no‐load healing period is validated by the experimental literature. In vivo histological data was scrutinized to identify the effect of early loading protocols on the bone‐implant interface. Several loading modes were identified. They were categorized into groups according to implant design and the type of prosthetic reconstruction, and by their ability to introduce a distinct magnitude of motion at the interface. Specific histologic responses of early loaded implants (i.e., fibrous repair or osseointegration) were suggested to be directly related to the specific combinations of the above parameters. Early loading per se was not found to be detrimental to osseointegration. Specifically, only excessive micromotion was directly implicated in the formation of fibrous encapsulation. The literature suggests that there is a critical threshold of micromotion above which fibrous encapsulation prevails over osseointegration. This critical level, however, was not zero micromotion as generally interpreted. Instead, the tolerated micromotion threshold was found to lie somewhere between 50 and 150 μm. Suggestions are made for the earliest loading time that achieves osseointegration. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 43: 192–203, 1998Keywords
This publication has 40 references indexed in Scilit:
- Predictable crestal bone remodelling around two porous‐coated titanium alloy dental implant designs. A radiographic study in dogs.Clinical Oral Implants Research, 1994
- Effects of mechanical stimulation on the differentiation of hard tissuesBiomaterials, 1993
- Biomechanical factors affecting the bone-dental implant interfaceClinical Materials, 1992
- Dental implant design–effect on bone remodelingJournal of Biomedical Materials Research, 1991
- Ultrastructural comparisons of ceramic and titanium dental implants in vivo: A scanning electron microscopic studyJournal of Biomedical Materials Research, 1989
- A Histological Evaluation of a Functional Endosseous, Porous-surfaced, Titanium Alloy Dental Implant System in the DogJournal of Dental Research, 1988
- Single-crystal sapphire endosseous dental implant loaded with functional stress?clinical and histological evaluation of peri-implant tissuesJournal of Oral Rehabilitation, 1988
- Observations on the Effect of Movement on Bone Ingrowth into Porous-Surfaced ImplantsClinical Orthopaedics and Related Research, 1986
- Radiographic and Morphologic Studies of Load-Bearing Porous-Surfaced Structured ImplantsClinical Orthopaedics and Related Research, 1981
- The Effect of Movement on the Holding Power of Screws in BoneClinical Orthopaedics and Related Research, 1975