USE OF THE TETRAZOLIUM ASSAY IN MEASURING THE RESPONSE OF HUMAN TUMOR-CELLS TO IONIZING-RADIATION
- 1 March 1990
- journal article
- research article
- Vol. 50 (5) , 1392-1396
Abstract
Three human tumor cell lines of widely differing radiosensitivity were used to examine the characteristics of the 3-[4,5-dimethyl(thiazol-2-yl)-3,5-diphery]tetradium bromide (MTT) assay and to select suitable conditions for its use in assessing the response of cells to ionizing radiation. The optimal concentration of MTT and the time of incubation of the cells with MTT were individualized for each cell line. The relationship between absorbance and cell number was not linear over the wide range of cell numbers that were used. A calibration curve of absorbance against cell number for each cell line was therefore used. Using the assay to quantify metabolically viable cells, growth curves of irradiated and unirradiated cells were constructed on days 0-14 after irradiation. Accurate surviving fractions could be calculated only when cells were in exponential growth. Using this modification to its interpretation, the MTT assay was able to provide a reproducible measure of survival, which compared well with clonogenic cell survival measurements. However, the necessity to optimize conditions of the MTT assay for each cell line severely limits its usefulness in determining the radiosensitivity of cells in primary human tumor cultures.This publication has 17 references indexed in Scilit:
- EVALUATION OF A TETRAZOLIUM-BASED SEMIAUTOMATED COLORIMETRIC ASSAY - ASSESSMENT OF RADIOSENSITIVITY1987
- EVALUATION OF A TETRAZOLIUM-BASED SEMIAUTOMATED COLORIMETRIC ASSAY - ASSESSMENT OF CHEMOSENSITIVITY TESTING1987
- TISSUE-CULTURE MODEL OF TRANSITIONAL CELL-CARCINOMA - CHARACTERIZATION OF 22 HUMAN UROTHELIAL CELL-LINES1986
- Rapid chemosensitivity testing of human lung tumor cells using the MTT assayCancer Chemotherapy and Pharmacology, 1986
- Rapid colorimetric assay for cell growth and survivalJournal of Immunological Methods, 1986
- A rapid colorimetric assay for the determination of IL-2-producing helper T cell frequenciesJournal of Immunological Methods, 1985
- Rapid colormetric assay for cell viability: Application to the quantitation of cytotoxic and growth inhibitory lymphokinesJournal of Immunological Methods, 1984
- A NOVEL DYE EXCLUSION METHOD FOR TESTING INVITRO CHEMOSENSITIVITY OF HUMAN-TUMORS1983
- Cell cycles in two cell lines of human bladder carcinoma.The Tohoku Journal of Experimental Medicine, 1977
- Differences in the response of leukaemia cells in tissue culture to nitrogen mustard and to dimethyl myleranBiochemical Pharmacology, 1961