Isotope pattern deconvolution for internal mass bias correction in the characterisation of isotopically enriched spikes
- 22 November 2007
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 23 (3) , 318-324
- https://doi.org/10.1039/b710595a
Abstract
Enriched spikes of 53Cr, 57Fe, 67Zn, 95Mo, 111Cd, 143Nd, 150Sm, 199Hg and 207Pb were characterised on a multi-collector ICP-MS instrument both in terms of isotopic composition and concentration. The isotopic composition of the spikes was determined using either a natural abundance or certified standard for mass bias correction, except for lead where thallium internal correction was used. It was observed that the use of weighted regression lines for mass bias correction provided similar or, in most cases, lower uncertainties in the isotopic composition of the spikes in comparison with unweighted regression lines or single ratio measurements. For the establishment of the spike concentration by reverse isotope dilution analysis, isotope pattern deconvolution was evaluated and mass bias could be corrected internally in each blend by minimising the variance of the multiple linear regression model. It was also observed that isotope pattern deconvolution with internal mass bias correction provided lower uncertainties in the concentration of the spikes in comparison with the usual procedure based on external mass bias correction.Keywords
This publication has 24 references indexed in Scilit:
- Characterisation of reference materials by isotope dilution mass spectrometryJournal of Analytical Atomic Spectrometry, 2007
- High-accuracy IDMS analysis of trace elements in wheat flour for the provision of reference values to a proficiency testing schemeJournal of Analytical Atomic Spectrometry, 2005
- Low uncertainty reverse isotope dilution ICP-MS applied to certifying an isotopically enriched Cd candidate reference material: A case studyJournal of the American Society for Mass Spectrometry, 2005
- Instrument response functions, mass bias and matrix effects in isotope ratio measurements and semi-quantitative analysis by single and multi-collector ICP-MSJournal of Analytical Atomic Spectrometry, 2003
- A comparison between quadrupole, double focusing and multicollector ICP-MS : Part II. Evaluation of total combined uncertainty in the determination of lead in biological matrices by isotope dilutionJournal of Analytical Atomic Spectrometry, 2001
- A comparison between quadrupole, double focusing and multicollector ICP-MS instruments : Part I. Evaluation of total combined uncertainty for lead isotope ratio measurementsJournal of Analytical Atomic Spectrometry, 2001
- A model for calculating dead time and mass discrimination correction factors from inductively coupled plasma mass spectrometry calibration curvesJournal of Analytical Atomic Spectrometry, 2000
- Validation of the analytical linearity and mass discrimination correction model exhibited by a multiple collector inductively coupled plasma mass spectrometer by means of a set of synthetic uranium isotope mixturesJournal of Analytical Atomic Spectrometry, 1995
- Sample analysis by on-line isotope dilution inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1989
- Ca isotope fractionation on the Earth and other solar system materialsGeochimica et Cosmochimica Acta, 1978