Step baroreflex response in awake patients undergoing carotid surgery: time- and frequency-domain analysis.
- 1 May 1998
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 274 (5) , H1590-H1597
- https://doi.org/10.1152/ajpheart.1998.274.5.h1590
Abstract
Step baroreceptor stimulation can provide an insight into the baroreflex control mechanism, yet this has never been done in humans. During carotid surgery under regional anesthesia, a step increase in baroreceptor stimulation occurs at carotid declamping immediately after removal of the intra-arterial atheromatous plaque. In 10 patients, the R-R interval and systolic and diastolic blood pressures (BP) were continuously recorded, and signals obtained within the time window from 10 min before until 10 min after carotid declamping were analyzed. Mean +/- SD time signals, power spectra, and transfer and coherence functions before and after declamping were calculated. Immediately after carotid declamping, both heart rate (HR) and BP declined in an exponential-like manner lasting 10.3 +/- 5.9 min, and their power spectra increased in the entire frequency range. Transfer function magnitude and coherence functions between BP and HR increased predominantly in the midfrequency region (approximately 0.1 Hz), with no change in phase function. Thus, in carotid endarterectomy patients, step increase in baroreceptor gain elicits a prolonged decline in HR and BP. Frequency analyses support the notion that the baroreflex control mechanism generates the midfrequency HR and BP variability, although other frequency regions are also affected.Keywords
This publication has 22 references indexed in Scilit:
- Decreased baroreflex sensitivity in patients with stable coronary artery disease is correlated with the severity of coronary narrowingThe American Journal of Cardiology, 1996
- Low-Frequency Spontaneous Fluctuations of R-R Interval and Blood Pressure in Conscious Humans: A Baroreceptor or Central Phenomenon?Clinical Science, 1994
- Mechanism of baroreceptor adaptation in dogs: attenuation of adaptation by the K+ channel blocker 4‐aminopyridine.The Journal of Physiology, 1993
- The Fast Flush Test Measures the Dynamic Response of the Entire Blood Pressure Monitoring SystemAnesthesiology, 1992
- Cardiovascular responses to stimulation of carotid baroreceptors in healthy subjectsClinical Science, 1988
- Left ventricular reflex control of venous return and systemic vascular capacitance in dogsCanadian Journal of Physiology and Pharmacology, 1988
- Time delays in the human baroreceptor reflexJournal of the Autonomic Nervous System, 1983
- Operational sensitivity and acute resetting of aortic baroreceptors in dogs.Circulation Research, 1981
- Baroreflex inhibition of the human sinus node: importance of stimulus intensity, duration, and rate of pressure change.The Journal of Physiology, 1977
- Deterministic nature of baroreceptor firingAmerican Journal of Physiology-Legacy Content, 1968