Abstract
An analysis of a coaxial-to-waveguide adaptor that incorporates a solid probe coated with a dielectric is presented. Based on this analysis, a computer algorithm is developed. The numerical results for the input impedance of the probe are presented and show good agreement with other analyses and experiments. The method presented includes the stage of analytical preprocessing and is computationally efficient.

This publication has 3 references indexed in Scilit: