Evaluation of factors affecting relationship between transcutaneous PO2 and probe temperature
- 1 October 1985
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 59 (4) , 1117-1127
- https://doi.org/10.1152/jappl.1985.59.4.1117
Abstract
Several studies on transcutaneous O2 probes have shown that the transcutaneous PO2 increases to .apprx. 80% of the arterial PO2 when the probe is heated to 44.degree. C. It is known whether this result reflects near-complete thermic arterialization or rather other factors such as the temperature-linked right shift of the hemoglobin O2-binding curve. In many clinical applications of transcutaneous probes the use of 44.degree. C is a major disadvantage because of the risk of skin burns. The development of new probes operating at lower temperatures is hampered by the lack of data on the temperature dependence of the factors influencing the relationship between the transcutaneous PO2 and the probe temperature. The present study attempts to estimate the temperature dependence of (1) the degree of arterialization of the blood in the skin capillaries, (2) the PO2 difference across the epidermis caused by the diffusion gradient and the epidermal O2 consumption, and (3) the arteriovenous saturation difference over the skin capillaries. The estimation is based on simultaneously measured transcutaneous PO2, PCO2, and argon partial pressure (PAr) values at seven different probe temperatures. The transcutaneous PCO2 is assumed equal to the mean capillary PCO2, which is used to calculate the mean capillary PO2 by the aid of a skin model. The O2 diffusion gradient is estimated from the transcutaneous PAr, and the PO2 difference caused by the epidermal O2 consumption is set equal to the difference between the mean capillary andd transcutaneous PO2 less the partial pressure difference caused by the diffusion gradient. The degree of arterialization was found to be 53% at 38.degree. C and 65% at 44.degree. C. The partial pressure difference caused by the epidermal O2 consumption decreased from 33 Torr at 38.degree. C to 6 Torr at 44.degree. C. The PO2 difference across the epidermis caused by the diffusion gradient was 7 Torr at 38.degree. C and 5 Torr at 44.degree. C. The arteriovenous saturation difference fell from 31% at 38.degree. C to 12% at 44.degree. C.This publication has 10 references indexed in Scilit:
- New transcutaneouspO2 probe based on mass spectrometry with low stirring effectMedical & Biological Engineering & Computing, 1985
- Numerical values of the classical Haldane coefficientJournal of Applied Physiology, 1984
- Transcutaneous and capillary pCO2 and pO2 measurements in healthy adults.Clinical Chemistry, 1983
- Transfer of oxygen, nitrogen, and carbon dioxide through normal adult human skinJournal of Applied Physiology, 1980
- Fast-responding flow-independent blood gas catheter for oxygen measurementJournal of Applied Physiology, 1980
- Skin Surface Carbon Dioxide Tension in Sick InfantsPediatrics, 1979
- Difference between end-tidal and arterial PCO2 in exerciseJournal of Applied Physiology, 1979
- Error in oxygen measurements in open systems owing to oxygen consumption in unstirred layerBiotechnology & Bioengineering, 1978
- In vivo calibration of flow-dependent blood gas cathetersJournal of Applied Physiology, 1978
- A-a difference in O2 tension and physiological dead space in normal manJournal of Applied Physiology, 1963