Effect of Cataract and Pupil Size on Image Quality With Confocal Scanning Laser Ophthalmoscopy
- 1 August 1997
- journal article
- case report
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 115 (8) , 983-990
- https://doi.org/10.1001/archopht.1997.01100160153003
Abstract
Objective: To determine the effect of pupil size and cataract on the reproducibility and image quality obtained with confocal scanning laser ophthalmoscopy. Methods: Three image series were obtained with a confocal scanning laser ophthalmoscope (Heidelberg Retina Tomograph, Heidelberg, Germany) before and after pupillary dilation in each of 39 subjects (8 normal subjects, 5 glaucoma suspects, and 26 patients with glaucoma). The cataract density was measured with both a lens opacity meter and the Lens Opacities Classification System III system. The image quality of each image series was subjectively scored on a scale of 0 (poor) to 9 (high) by 2 independent observers who were unaware of the cataract density and pupil size during image acquisition. The image quality and reproducibility were objectively evaluated using the SD of the mean topography image of each subject. Results: The mean pupil diameter in all subjects before and after dilation was 2.5±0.8 mm and 5.8±1.4 mm, respectively. After pupillary dilation, both the mean image quality score and mean SD of the mean topography image improved (from 4.5±3.5 to 7.4±2.3 and from 48.6±18.8 μm to 35.6±15.5 μm, respectively). The quality score of the images that were obtained before pupillary dilation was associated with the pupil size and density of nuclear and posterior subcapsular cataracts. The SD of the mean topography images that were obtained before pupillary dilation increased with a decreasing pupil size (P=.003) and an increasing density of the nuclear (P<.03), cortical (P=.02), and posterior subcapsular (P=.002) opacity. Conclusions: Although pupillary dilation improved the image quality in most subjects, the improvement was sometimes small. Those subjects with small undilated pupils and/or cataracts may benefit most from pupillary dilation.Keywords
This publication has 9 references indexed in Scilit:
- Sources of Variability of Topometric Data With a Scanning Laser OphthalmoscopeArchives of Ophthalmology (1950), 1996
- Regional Test-Retest Variability of Confocal Scanning Laser TomographyAmerican Journal of Ophthalmology, 1995
- Optic nerve head analyzer and Heidelberg retina tomograph: relative error and reproducibility of topographic measurements in a model eye with simulated cataractAlbrecht von Graefes Archiv für Ophthalmologie, 1995
- Test-Retest Variability of Topographic Measurements With Confocal Scanning Laser Tomography in Patients With Glaucoma and Control SubjectsAmerican Journal of Ophthalmology, 1994
- Reproducibility of the Optic Nerve Head Topography with a New Laser Tomographic Scanning DeviceOphthalmology, 1994
- Effect of Repetitive Imaging on Topographic Measurements of the Optic Nerve HeadArchives of Ophthalmology (1950), 1993
- Reproducibility of Topographic Measurements of the Normal and Glaucomatous Optic Nerve Head With the Laser Tomographic ScannerAmerican Journal of Ophthalmology, 1991
- Evaluation of the 701 interzeag lens opacity meterAlbrecht von Graefes Archiv für Ophthalmologie, 1990
- Quantitative assessment of the optic nerve head with the laser tomographic scannerInternational Ophthalmology, 1989