Rapid identification of comigrating gel‐isolated proteins by ion trap‐mass spectrometry
- 1 May 1998
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 19 (6) , 968-980
- https://doi.org/10.1002/elps.1150190612
Abstract
In the search for novel nuclear binding proteins, two bands from a sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) gel were analyzed and each was found to contain a number of proteins that subseqently were identified by tandem mass spectrometry (MS/MS) on a quadrupole ion trap instrument. The bands were digested with trypsin in situ on a polyvinylidence difluoride (PVDF) membrane following electroblot transfer. Analysis of a 2.5% aliquot of each peptide mixture by matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) followed by an intial database search with the peptide mases failed to identify the proteins. The peptides were separated by reversed-phase capillary high performance liquid chromatography (HPLC) in anticipation of subsequent Edman degradation, but mass analysis of the chromatographic fractions by MALDI-MS revealed multiple, coeluting peptides that precluded this approach. Selected fractions were analyzed by capillary HPLC-electropspray ionization-ion trap mass spectrometry. Tandem mass spectrometry provided significant fragmentation from which full or partialsequence was deduced for a number of peptides. Two stages of fragmentation (MS3) were used in one case to determine additional dequence. Database searches, each using a single peptide mass plus partial sequence, identified four proteins from a single electrophoretic band at 45 kDa, and four proteins from a second band at 60 kDa. Many of these proteins were derived from human keratin. The protein identifications were corroborated by the presence ofmultiple matching peptide masses in the MALDI-MS spectra. In addition, a novel sequence, not found in protein or DNA databases, wes determined by interpretation of the MS/MS data. These results demonstrate the power of the quadrupole ion trap for the identification of multiple proteins in a mixture, and for de novo determination of peptide sequence. Reanalysis of the fragmentation data with a modified database searching algorithm showed that the same sets of proteins were identified from a limited number of fragment ion masses, in the absence of mass spectral interpretation or amino acid sequence. The implications for protein identification solely from fragment ion masses are discussed, including advantages for low signal levels, for a reduction of the necessary interpretation expertise, and for increased speed.Keywords
This publication has 43 references indexed in Scilit:
- Peer Reviewed: Internet-Based Analytical Chemistry Resources: A Model ProjectAnalytical Chemistry, 1996
- Application of combined mass spectrometry and partial amino acid sequence to the identification of gel‐separated proteinsElectrophoresis, 1996
- Simplified High-Sensitivity Sequencing of a Major Histocompatibility Complex Class I-Associated Immunoreactive Peptide Using Matrix-Assisted Laser Desorption/Ionization Mass SpectrometryAnalytical Biochemistry, 1995
- Protein identification in DNA databases by peptide mass fingerprintingProtein Science, 1994
- Peptide Mass Maps: A Highly Informative Approach to Protein IdentificationAnalytical Biochemistry, 1993
- Protein Identification by Mass Profile FingerprintingBiochemical and Biophysical Research Communications, 1993
- Rapid identification of proteins by peptide-mass fingerprintingCurrent Biology, 1993
- Identifying proteins from two-dimensional gels by molecular mass searching of peptide fragments in protein sequence databases.Proceedings of the National Academy of Sciences, 1993
- Use of mass spectrometric molecular weight information to identify proteins in sequence databasesJournal of Mass Spectrometry, 1993
- Peptide sequencing by magnetic deflection tandem mass spectrometryBiochemical Journal, 1987