Electro-hydrodynamic atomization of drug solutions for inhalation purposes
- 1 December 2001
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 91 (6) , 2735-2741
- https://doi.org/10.1152/jappl.2001.91.6.2735
Abstract
Monodisperse aerosols show therapeutic advantages, but they are difficult to generate. A new method (electrohydrodynamic atomization) is described. A high voltage is applied to a nozzle through which a solution, containing dissolved drug, is pumped. At the nozzle tip, a liquid cone is formed and a stream of monodisperse droplets is released. The droplet diameter is governed by the density, conductivity, and the flow rate of the fluid. The droplets are charged and need to be neutralized. Therefore, a corona discharge system is used. Methylparahydroxybenzoate was used as a model drug, and additional data were generated by using beclomethasone dipropionate (BDP). At a flow rate of 1 ml/h and 0.5% methylparahydroxybenzoate, 1.58-μm particles were produced with a geometric SD of 1.18. Increasing the flow rate to 3 ml/h and the concentration to 3% resulted in 4.55-μm particles with a geometric SD of 1.29. The experiments with BDP resulted in similar particle sizes. The mass of BDP was found to range between 1.42 and 6 μg/l air. Aqueous solutions cannot be sprayed by using this setup. This method can be used to deliver antiasthma drugs to patients.Keywords
This publication has 20 references indexed in Scilit:
- Electrohydrodynamic spraying functioning modes: a critical reviewPublished by Elsevier ,2003
- A review of liquid atomization by electrical meansPublished by Elsevier ,2003
- Respimat® (a New Soft Mist Inhaler) Delivering Fenoterol plus Ipratropium Bromide Provides Equivalent Bronchodilation at Half the Cumulative Dose Compared with a Conventional Metered Dose Inhaler in Asthmatic PatientsRespiration, 2000
- ELECTROHYDRODYNAMIC ATOMIZATION IN THE CONE–JET MODE PHYSICAL MODELING OF THE LIQUID CONE AND JETJournal of Aerosol Science, 1999
- Evaluation of the Measurement Performance of the Scanning Mobility Particle Sizer and Aerodynamic Particle SizerAerosol Science and Technology, 1999
- Sampling Efficiency of the Tsi Aerodynamic Particle SizerInstrumentation Science & Technology, 1998
- The lung deposition of salbutamol, directly labelled with technetium-99m, delivered by pressurised metered dose and dry powder inhalersInternational Journal of Pharmaceutics, 1993
- Generation of micron-sized droplets from the Taylor coneJournal of Aerosol Science, 1992
- Charge Injection Electrostatic Atomizer ModelingAerosol Science and Technology, 1990
- The spinning-top aerosol generator—Improving the performanceJournal of Aerosol Science, 1984