Accuracy of Positron Emission Tomography for Diagnosis of Pulmonary Nodules and Mass Lesions
Top Cited Papers
- 21 February 2001
- journal article
- research article
- Published by American Medical Association (AMA) in JAMA
- Vol. 285 (7) , 914-924
- https://doi.org/10.1001/jama.285.7.914
Abstract
ContextFocal pulmonary lesions are commonly encountered in clinical practice, and positron emission tomography (PET) with the glucose analog 18-fluorodeoxyglucose (FDG) may be an accurate test for identifying malignant lesions.ObjectiveTo estimate the diagnostic accuracy of FDG-PET for malignant focal pulmonary lesions.Data SourcesStudies published between January 1966 and September 2000 in the MEDLINE and CANCERLIT databases; reference lists of identified studies; abstracts from recent conference proceedings; and direct contact with investigators.Study SelectionStudies that examined FDG-PET or FDG with a modified gamma camera in coincidence mode for diagnosis of focal pulmonary lesions; enrolled at least 10 participants with pulmonary nodules or masses, including at least 5 participants with malignant lesions; and presented sufficient data to permit calculation of sensitivity and specificity were included in the anaylsis.Data ExtractionTwo reviewers independently assessed study quality and abstracted data regarding prevalence of malignancy and sensitivity and specificity of the imaging test. Disagreements were resolved by discussion.Data SynthesisWe used a meta-analytic method to construct summary receiver operating characteristic curves. Forty studies met inclusion criteria. Study methodological quality was fair. Sample sizes were small and blinding was often incomplete. For 1474 focal pulmonary lesions of any size, the maximum joint sensitivity and specificity (the upper left point on the receiver operating characteristic curve at which sensitivity and specificity are equal) of FDG-PET was 91.2% (95% confidence interval, 89.1%-92.9%). In current practice, FDG-PET operates at a point on the summary receiver operating characteristic curve that corresponds approximately to a sensitivity and specificity of 96.8% and 77.8%, respectively. There was no difference in diagnostic accuracy for pulmonary nodules compared with lesions of any size (P = .43), for semiquantitative methods of image interpretation compared with qualitative methods (P = .52), or for FDG-PET compared with FDG imaging with a modified gamma camera in coincidence mode (P = .19).ConclusionsPositron emission tomography with 18-fluorodeoxyglucose is an accurate noninvasive imaging test for diagnosis of pulmonary nodules and larger mass lesions, although few data exist for nodules smaller than 1 cm in diameter. In current practice, FDG-PET has high sensitivity and intermediate specificity for malignancy.Keywords
This publication has 48 references indexed in Scilit:
- Usefulness of positron emission tomography imaging in the management of lung cancerCurrent Opinion in Pulmonary Medicine, 1999
- Current role of positron emission tomography in thoracic oncologyThorax, 1998
- Oncologic diagnosis with 2-[fluorine-18]fluoro-2-deoxy-D-glucose imaging: dual-head coincidence gamma camera versus positron emission tomographic scanner.Radiology, 1998
- The current status of clinical PET imagingClinical Radiology, 1996
- 18F-fluorodeoxyglucose PET scans in lung cancer.Thorax, 1996
- Satellite PET and lung cancer: A prospective study in surgical patients : Slosman DO, Spiliopoulos A, Couson F, Nicod L, Louis O, Lemoine R et al. Division of Nuclear Medicine, University Hospital, I211 Geneve 14. Nucl Med Commun 1993;14:955–61Lung Cancer, 1994
- Focal pulmonary abnormalities: evaluation with F-18 fluorodeoxyglucose PET scanning.Radiology, 1993
- Determining the likelihood of malignancy in solitary pulmonary nodules with Bayesian analysis. Part I. Theory.Radiology, 1993
- MANAGING SOLITARY PULMONARY NODULES - THE CHOICE OF STRATEGY IS A CLOSE CALLPublished by Elsevier ,1986
- Solitary pulmonary nodules: CT assessment.Radiology, 1986