Surface‐attached PEO in the form of activated pluronic with immobilized factor H reduces both coagulation and complement activation in a whole‐blood model
- 25 October 2005
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 76A (1) , 25-34
- https://doi.org/10.1002/jbm.a.30377
Abstract
In the present work we have bound Pluronic™, a class of triblock copolymers consisting of a block of polypropylene oxide (PPO) surrounded on each side by polyethylene oxide (PEO) blocks, to polystyrene surfaces and investigated the thrombogenicity and complement activation of this construct upon exposure to whole blood. The surface was highly inert towards coagulation, unfortunately at the expense of increased complement activation. We, therefore, as an alternative approach, used End-Group Activated Pluronic to conjugate factor H, a regulator of complement activation (RCA), to the surface. The bound factor H did not detach from the surface upon incubation with human serum. Furthermore, factor H bound in a physiological conformation could to a significant degree attenuate complement activation at the Pluronic™ surface. Thus, we have created a hybrid surface in which the coagulation-inert properties of the original Pluronic™ are supplemented with a specific complement-inhibitory effect. Medical device technology includes numerous potential applications for crosslinkers that are capable of specifically binding biomolecules to surfaces with retained activity. These applications include coupling of functional biomolecules to biomedical devices such as stents and grafts. The biomolecule may be an RCA, antibody, or other beneficial ligand. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2006Keywords
This publication has 38 references indexed in Scilit:
- Whole blood coagulation on protein adsorption-resistant PEG and peptide functionalised PEG-coated titanium surfacesBiomaterials, 2005
- Biomaterial-associated thrombosis: roles of coagulation factors, complement, platelets and leukocytesBiomaterials, 2004
- In vitro biocompatibility assessment of sulfonated polyrotaxane‐immobilized polyurethane surfacesJournal of Biomedical Materials Research Part A, 2003
- Serum protein adsorption and platelet adhesion on pluronic™-adsorbed polysulfone membranesBiomaterials, 2003
- Influence of test protocol in determining the blood response to model polymersJournal of Materials Science: Materials in Medicine, 2002
- Biocompatibility and Functional Performance of a Polyethylene Glycol Acid-Grafted Cellulosic Membrane for HemodialysisThe International Journal of Artificial Organs, 2000
- Plasma protein interactions with Pluronic™-treated colloidsColloids and Surfaces B: Biointerfaces, 1996
- Surface modification of nanoparticles by PEO/PPO block copolymers to minimize interactions with blood components and prolong blood circulation in ratsBiomaterials, 1993
- Prevention of protein adsorption and platelet adhesion on surfaces by PEO/PPO/PEO triblock copolymersBiomaterials, 1992
- Identification of rapid changes at plasma–solid interfacesJournal of Biomedical Materials Research, 1969