Comparison of the Luminex xTAG Respiratory Viral Panel with xTAG Respiratory Viral Panel Fast for Diagnosis of Respiratory Virus Infections
- 1 May 2011
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 49 (5) , 1738-1744
- https://doi.org/10.1128/jcm.02090-10
Abstract
Nucleic acid tests are sensitive and specific and provide a rapid diagnosis, making them invaluable for patient and outbreak management. Multiplex PCR assays have additional advantages in providing an economical and comprehensive panel for many common respiratory viruses. Previous reports have shown the utility of the xTAG respiratory viral panel (RVP) assay manufactured by Luminex Molecular Diagnostics for this purpose. A newer generation of this kit, released in Canada in early 2010, is designed to simplify the procedure and reduce the turnaround time by about 24 h. The assay methodology and targets included in this version of the kit are different; consequently, the objective of this study was to compare the detection of a panel of respiratory viral targets using the older Luminex xTAG RVP (RVP Classic) assay with that using the newer xTAG RVP Fast assay. This study included 334 respiratory specimens that had been characterized for a variety of respiratory viral targets; all samples were tested by both versions of the RVP assay in parallel. Overall, the RVP Classic assay was more sensitive than the RVP Fast assay (88.6% and 77.5% sensitivities, respectively) for all the viral targets combined. Targets not detected by the RVP Fast assay included primarily influenza B virus, parainfluenza virus type 2, and human coronavirus 229E. A small number of samples positive for influenza A virus, respiratory syncytial virus B, human metapneumovirus, and parainfluenza virus type 1 were not detected by the RVP Classic assay and in general had low viral loads.Keywords
This publication has 22 references indexed in Scilit:
- Emergence of a Novel Swine-Origin Influenza A (H1N1) Virus in HumansNew England Journal of Medicine, 2009
- Diagnosis and epidemiological studies of human metapneumovirus using real-time PCRJournal of Clinical Virology, 2007
- Development of a Respiratory Virus Panel Test for Detection of Twenty Human Respiratory Viruses by Use of Multiplex PCR and a Fluid Microbead-Based AssayJournal of Clinical Microbiology, 2007
- MultiCode-PLx System for Multiplexed Detection of Seventeen Respiratory VirusesJournal of Clinical Microbiology, 2007
- High-Throughput, Sensitive, and Accurate Multiplex PCR-Microsphere Flow Cytometry System for Large-Scale Comprehensive Detection of Respiratory VirusesJournal of Clinical Microbiology, 2007
- Simultaneous Detection and High-Throughput Identification of a Panel of RNA Viruses Causing Respiratory Tract InfectionsJournal of Clinical Microbiology, 2007
- Direct Screening of Clinical Specimens for Multiple Respiratory Pathogens Using the Genaco Respiratory Panels 1 and 2Diagnostic Molecular Pathology, 2006
- Real-Time Quantitative PCR Assays for Detection andMonitoring of Pathogenic Human Viruses in ImmunosuppressedPediatricPatientsJournal of Clinical Microbiology, 2004
- Simultaneous detection of fourteen respiratory viruses in clinical specimens by two multiplex reverse transcription nested‐PCR assaysJournal of Medical Virology, 2004
- Development and evaluation of NucliSens® Basic Kit NASBA for diagnosis of parainfluenza virus infection with ‘end-point’ and ‘real-time’ detectionJournal of Virological Methods, 2003