An interferometer has been developed which makes use of the free surface of a liquid as a reflector. The emitter is an optically plane quartz crystal which is held perfectly horizontal at the bottom of a vertical liquid column. Changes in the column height produce the effects which are used to measure absorption in the liquid. A sensitive method of adding liquid makes the instrument usable at frequencies well above six megacycles. The leveling is sensitive and positive.