An analytical approach for compensation of non-uniform attenuation in cardiac SPECT imaging
- 1 October 1995
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 40 (10) , 1677-1693
- https://doi.org/10.1088/0031-9155/40/10/009
Abstract
Photon attenuation can reduce the diagnostic accuracy of cardiac SPECT imaging. Bellini et al. have previously derived a mathematically exact method to compensate for attenuation in a uniform attenuator. Since the human thorax contains structures with differing attenuation properties, non-uniform attenuation compensation is required in cardiac SPECT. Given an estimate of the patient attenuation map, we show that the Bellini attenuation compensation method can be used in cardiac SPECT to provide a quantitatively accurate reconstruction of a central region in the image which includes the heart and surrounding soft tissue. Simulations using a mathematical cardiac-torso phantom were conducted to evaluate the Bellini method and to compare its performance to the ML-EM iterative algorithm, and to 180 degrees and 360 degrees filtered backprojection (FBP) with no attenuation compensation. 'Bulls-eye' polar maps and circumferential profiles showed that both the Bellini method and the ML-EM algorithm provided quantitatively accurate reconstructions of the myocardium, with a substantial reduction in attenuation-induced artifacts that were observed in the FBP images. The computational load required to implement the Bellini method is approximately equivalent to that required for one iteration of the ML-EM algorithm, thus it is suitable for routine clinical use.Keywords
This publication has 19 references indexed in Scilit:
- An analytical approach to quantitative reconstruction of non-uniform attenuated brain SPECTPhysics in Medicine & Biology, 1994
- Noniterative compensation for the distance-dependent detector response and photon attenuation in SPECT imagingIEEE Transactions on Medical Imaging, 1994
- Application of convergent-beam collimation and simultaneous transmission emission tomography to cardiac single-photon emission computed tomographySeminars in Nuclear Medicine, 1994
- The effect of intrinsic attenuation correction methods on the stationarity of the 3-D modulation transfer function of SPECTMedical Physics, 1992
- CT filtration aliasing artifactsIEEE Transactions on Medical Imaging, 1991
- Characterization of the modulation transfer function of discrete filtered backprojectionIEEE Transactions on Medical Imaging, 1989
- Image reconstruction algorithm for single-photon-emission computed tomography with uniform attenuationPhysics in Medicine & Biology, 1989
- The circular harmonic transform for SPECT reconstruction and boundary conditions on the Fourier transform of the sinogramIEEE Transactions on Medical Imaging, 1988
- Quantitative Image Reconstruction with Weighted Backprojection for Single Photon Emission Computed TomographyJournal of Computer Assisted Tomography, 1983
- Compensation of tissue absorption in emission tomographyIEEE Transactions on Acoustics, Speech, and Signal Processing, 1979