Radioactivity in the Light Ion Fusion Target Development Facility
- 1 July 1985
- journal article
- research article
- Published by Taylor & Francis in Fusion Technology
- Vol. 8 (1P2B) , 1396-1401
- https://doi.org/10.13182/fst85-a39962
Abstract
Radioactivity and biological dose calculations have been performed for the target chamber of the Target Development Facility (TDF). Two conventional shield designs are considered. One has the target chamber submerged 3 m from the surface of a borated water pool, the other has the chamber surrounded by approximately 250 cm of concrete. The first wall materials, Al-6061 and 2-1/4 Cr-1 Mo steel and the ion beam targets, one made from BeO2 and W and the other from CH2 and Au, are investigated. Shielding designs are presented that reduce the dose from each of these choices of shield, first wall and target material to acceptable levels.Keywords
This publication has 3 references indexed in Scilit:
- Fatigue Strength Analysis of the Sandia Target Development Facility Reaction ChamberFusion Technology, 1985
- Neutron Activation and Shielding of the Light ion Fusion Target Development FacilityNuclear Technology - Fusion, 1983
- Engineering Compendium on Radiation ShieldingPublished by Springer Nature ,1975