Comments On the Effect of Gas Velocity On Oxygen Index Measurements
- 1 November 1983
- journal article
- research article
- Published by SAGE Publications in Journal of Fire Sciences
- Vol. 1 (6) , 459-464
- https://doi.org/10.1177/073490418300100605
Abstract
For certain materials, the velocity of the mixed gas stream used in an oxygen index determination has been reported to exert a strong influence on the ex perimental result. It is now possible to rationalise these reported dependences which are shown to result from the form of column used in the test. A proposed modification to the column outlet eliminates the dependence of oxygen index on gas velocity over the range of gas velocity permitted by the testing standards.Keywords
This publication has 2 references indexed in Scilit:
- A correction to standard test equations for use with the hot flammability test apparatus (HFTA)Fire and Materials, 1981
- Anomalous behaviour in certain versions of the critical oxygen index testFire and Materials, 1981