Comparative assessment of dual-photon absorptiometry and dual-energy radiography.
- 1 January 1990
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 174 (1) , 223-228
- https://doi.org/10.1148/radiology.174.1.2294552
Abstract
Dual-energy bone densitometry can be performed with two types of scanners. The traditional dual-photon absorptiometry (DPA) machines use an isotope source, whereas the newly introduced dual-energy radiography (DER) devices use an incorporated x-ray tube. The authors evaluated the performance of DPA and DER devices at their institution. The short-term precision error in vivo was 1.2% for femoral neck measurements with DER. Long-term precision error in vitro was reduced from 1.30% (DPA) to 0.44% (DER). The scanning time for both spine and hip measurements was reduced from 20-40 minutes to 6-7 minutes. Intraosseous fat sensitivity remained the same, at a level of 12 mg/cm2 apparent decrease of bone mineral density (BMD) per 10% fat by volume change, and for both devices there was no shift in BMD when phantom thickness was increased by 1.5 inches. The correlation of DPA and DER was high: r = .98 for the spine and r = .95 for the femoral neck. Correlation of DPA versus quantitative computed tomography (CT) (r = .83) and DER versus quantitative CT (r = .85) was good. The advent of DER represents a significant advance for the field of bone densitometry.This publication has 15 references indexed in Scilit:
- Comparison of Dual-Energy X-Ray Absorptiometry and Dual Photon Absorptiometry for Bone Mineral Measurements of the Lumbar SpineMayo Clinic Proceedings, 1988
- Quantitative Digital RadiographyVersusDual Photon Absorptiometry of the Lumbar Spine*Journal of Clinical Endocrinology & Metabolism, 1988
- Dual energy radiography (DER): A preliminary comparative studyCalcified Tissue International, 1988
- Precision error in dual-photon absorptiometry related to source age.Radiology, 1988
- USEFULNESS OF REGIONAL BONE MEASUREMENTS IN PATIENTS WITH OSTEOPOROTIC FRACTURES OF THE SPINE AND DISTAL FOREARM1987
- Bone mineral content in early-postmenopausal and postmenopausal osteoporotic women: comparison of measurement methods.Radiology, 1986
- Should Perimenopausal Women Be Screened for Osteoporosis?Annals of Internal Medicine, 1986
- Rates of bone loss in the appendicular and axial skeletons of women. Evidence of substantial vertebral bone loss before menopause.Journal of Clinical Investigation, 1986
- Quantitative Computed Tomography of Vertebral Spongiosa: A Sensitive Method for Detecting Early Bone Loss After OophorectomyAnnals of Internal Medicine, 1982
- Bone-mineral content of the femoral neck and spine versus the radius or ulnaJournal of Bone and Joint Surgery, 1977