Detection and Measurement of Aromatic Hydrocarbons in the Air by a Coated Piezoelectric Crystal Detector
- 1 January 1975
- journal article
- research article
- Published by Taylor & Francis in Environmental Letters
- Vol. 10 (3) , 237-246
- https://doi.org/10.1080/00139307509435825
Abstract
Nujol with trans-IrCl(CO)(PPh3)2 complex, is used as a coating for piezoelectric crystal detector. The device preferentially detects some aromatic hydrocarbons in air over aliphatic ones. The effect of atmospheric moisture is minimal.Keywords
This publication has 11 references indexed in Scilit:
- The detection of ammonia and nitrogen dioxide at the parts per billion level with coated piezoelectric crystal detectorsAnalytica Chimica Acta, 1975
- Measurement of SO2in Air Using Coated Piezoelectric Crystal DetectorsEnvironmental Letters, 1975
- A new design and coatings for piezoelectric crystals in measurement of trace amounts of sulfur dioxideAnalytica Chimica Acta, 1974
- Effects of gasoline aromatic and lead content on exhaust hydrocarbon reactivityEnvironmental Science & Technology, 1974
- Analytical performance of the piezoelectric crystal detectorJournal of Chromatography A, 1974
- A Gas Chromatograph Based on the Piezoelectric DetectorJournal of Chromatographic Science, 1971
- Monitoring of hydrogen, methane, and hydrocarbons in the atmosphereEnvironmental Science & Technology, 1970
- Oxidation of nitric oxide in the presence of ultraviolet light and hydrocarbonsEnvironmental Science & Technology, 1969
- Hydrocarbon reactivity and eye irritationEnvironmental Science & Technology, 1968
- Reversible activation of covalent molecules by transition-metal complexes. The role of the covalent moleculeAccounts of Chemical Research, 1968