Radioimmunoassay of human eosinophil cationic protein (ECP) by an improved method. Establishment of normal levels in serum and turnover in vivo
- 1 September 1991
- journal article
- Published by Wiley in Clinical and Experimental Allergy
- Vol. 21 (5) , 561-567
- https://doi.org/10.1111/j.1365-2222.1991.tb00847.x
Abstract
A radioimmunoassay was developed allowing measurement of the cytotoxic cationic ECP. The assay, which has a total incubation time of 3.5 hr, is a double antibody assay with radiolabelled ECP, covering the concentration range of 2-200 micrograms/l. Performance data show a detection limit of less than 2 micrograms/l and a cross-reactivity with eosinophil protein X (EPX/EDN) of less than 0.06%. The coefficient of variation (%) within the measuring range was, within assay 4.8-10.4, and total 6.6-12.0. The assay is useful for measurement in various body fluids including serum, nasal secretions and bronchoalveolar lavage fluid, and dilution of samples prior to analysis was generally not required. Sera from 100 apparently healthy individuals revealed a geometric mean of 6.0 micrograms ECP/l and a range (95%) of 2.3-15.9 micrograms/l. The elimination rate of ECP, t1/2, in vivo was estimated to be 65 min when ECP was measured in serum. Comparisons between this assay and a method previously described showed that the new method is superior with regard to precision and assay procedure.Keywords
This publication has 18 references indexed in Scilit:
- Serum and plasma measurements of neutrophil granule proteins during cardiopulmonary bypass: A model to estimate human turnover of lactoferrin and myeloperoxidaseEuropean Journal of Haematology, 1987
- Biochemical and functional similarities between human eosinophil-derived neurotoxin and eosinophil cationic protein: homology with ribonuclease.Proceedings of the National Academy of Sciences, 1986
- Human Eosinophil Cationic Proteins (ECP and EPX) and Their Suppressive Effects on Lymphocyte ProliferationImmunobiology, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Leukocyte Elastase Release during Blood CoagulationJournal of Clinical Investigation, 1982
- Morphological studies on the killing of schistosomula of Schistosoma mansoni by human eosinophil and neutrophil cationic proteins in vitroParasite Immunology, 1981
- Radioimmunoassay of Human Eosinophil Cationic ProteinBritish Journal of Haematology, 1977
- Comparative properties of the Charcot-Leyden crystal protein and the major basic protein from human eosinophils.Journal of Clinical Investigation, 1976
- Uptake of proteinase-α-macroglobulin complexes by macrophages☆Biochimica et Biophysica Acta (BBA) - General Subjects, 1975
- The Neutral Proteases of Human GranulocytesEuropean Journal of Biochemistry, 1974