Paraplegia as a Complication of Percutaneous Vertebroplasty With Polymethylmethacrylate
- 1 October 2002
- journal article
- case report
- Published by Wolters Kluwer Health in Spine
- Vol. 27 (19) , E419-E422
- https://doi.org/10.1097/00007632-200210010-00022
Abstract
A case report and review of the literature are presented. To present the first case of paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate in osteoporotic compression fracture. Complications of percutaneous vertebroplasty with polymethylmethacrylate (PMMA) for the treatment of osteoporotic compression fracture were found to be rare and minor, except in two cases of major neurologic complication. The reported case is that of a 66-year-old woman with multilevel vertebral osteopenia and compression fractures. Percutaneous vertebroplasty using polymethylmethacrylate was performed at three vertebral bodies (L2, L1, and T11) using careful techniques including venography, large cannula, proper preparation and amount of polymethylmethacrylate, and continuous visualization with fluoroscopy. Immediately after surgery, the patient had complete motor and sensory deficits at T11. Computed tomography scan showed spinal cord compression caused by venous leakage of polymethylmethacrylate. In anticipation of recovery from paraplegia, posterior decompression was performed from L2 to T10. Percutaneous vertebroplasty with polymethylmethacrylate is not as simple and risk free as advocated in the literature. Careful safeguards and modifications are needed for the procedure, and new and physiologic material could be substituted for polymethylmethacrylate.Keywords
This publication has 16 references indexed in Scilit:
- New Technologies in SpineSpine, 2001
- Long‐term observations of vertebral osteoporotic fractures treated by percutaneous vertebroplastyRheumatology, 2000
- Biomechanical Evaluation of a New Bone Cement for Use in VertebroplastySpine, 2000
- Percutaneous Vertebroplasty for Pain Relief and Spinal StabilizationSpine, 2000
- Acute osteoporotic vertebral collapse: open study on percutaneous injection of acrylic surgical cement in 20 patients.American Journal of Roentgenology, 1999
- The Use of an Injectable, Biodegradable Calcium Phosphate Bone Substitute for the Prophylactic Augmentation of Osteoporotic Vertebrae and the Management of Vertebral Compression FracturesSpine, 1999
- PERCUTANEOUS VERTEBROPLASTY WITH POLYMETHYLMETHACRYLATERadiologic Clinics of North America, 1998
- Percutaneous vertebroplasty: state of the art.RadioGraphics, 1998
- Future DirectionsSpine, 1997
- Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up.Radiology, 1996