Sensitivity and Specificity of the GDx: Clinical Judgment of Standard Printouts Versus the Number
- 1 April 2003
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 12 (2) , 129-133
- https://doi.org/10.1097/00061198-200304000-00007
Abstract
The Number is a standard parameter of the GDx that reportedly distinguishes normal and glaucomatous eyes. The authors evaluated the sensitivity and specificity of the Number and examined whether expert clinical judgment of GDx printouts leads to a better separation. Two experienced observers judged 800 GDx scans on 400 randomly presented printouts from 200 glaucoma patients and 200 age-matched normal subjects. The diagnosis was based on the symmetry analysis printout and was per patient rather than per eye. The observers assessed sensitivity for all glaucoma patients together, and separately for mild, moderate, and severe glaucoma. Their specificity was determined in the group of normal subjects. The same procedure was performed for the Number, at various critical values. Both observers discriminated better than the Number. At a critical value of 23, the specificity of the Number was 81.5%, which matched the lowest specificity of the 2 observers: 82.5% and 92.0% for observers 1 and 2, respectively. At these specificities, the sensitivity of the 2 observers and of the Number were 92.0%, 89.5%, and 85.5%, respectively. The sensitivity increased with the severity of glaucoma. The Kappa values for intraobserver agreement were 0.80 and 1.0. The Number yielded acceptable sensitivity and specificity values at a critical value of 23 in this test population. However, the clinical judgments of the printouts by both expert observers resulted in a better separation between normal and glaucomatous eyes, particularly in the group with mild glaucoma.Keywords
This publication has 25 references indexed in Scilit:
- Glaucoma Screening Using the Scanning Laser PolarimeterJournal of Glaucoma, 2000
- Retinal nerve fiber layer measurement by nerve fiber analyzer in normal subjects and patients with glaucomaOphthalmology, 1999
- Detection of Glaucoma With Scanning Laser PolarimetryArchives of Ophthalmology (1950), 1998
- Differentiating patients with glaucoma from glaucoma suspects and normal subjects by nerve fiber layer assessment with scanning laser polarimetry1,2Ophthalmology, 1998
- Retinal Nerve Fiber Layer Thickness within the Area of Apparently Normal Visual Field in Normal-Tension Glaucoma with Hemifield DefectJournal of Glaucoma, 1998
- Quantitative Nerve Fiber Layer Measurement using Scanning Laser Polarimetry and Modulation Parameters in the Detection of GlaucomaJournal of Glaucoma, 1998
- Clinical evaluation of scanning laser polarimetry: II Polar profile shape analysisBritish Journal of Ophthalmology, 1998
- Scanning laser polarimetry of the retinal nerve fibre layer in primary open angle and capsular glaucomaBritish Journal of Ophthalmology, 1997
- Scanning Laser Polarimetry to Measure the Nerve Fiber Layer of Normal and Glaucomatous EyesAmerican Journal of Ophthalmology, 1995
- Histopathologic Validation of Fourier-Ellipsometry Measurements of Retinal Nerve Fiber Layer ThicknessArchives of Ophthalmology (1950), 1990