A Comparison Study of Plantar Foot Pressure in a Standardized Shoe, Total Contact Cast, and Prefabricated Pneumatic Walking Brace
- 1 January 1997
- journal article
- research article
- Published by SAGE Publications in Foot & Ankle International
- Vol. 18 (1) , 26-33
- https://doi.org/10.1177/107110079701800106
Abstract
Total contact casting is the current recommended treatment for Wagner Stage 1 and 2 neuropathic plantar ulcers. The rationale for this treatment includes the equalization of plantar foot pressures and generalized unweighting of the foot through a total contact fit at the calf. Total contact casting requires meticulous technique and multiple cast applications to avoid complications before ulcer healing. An alternative to total contact casting is the use of a prefabricated brace designed to maintain a total contact fit. This study compares plantar foot pressure metrics in a standardized shoe (SS), total contact cast (TCC), and prefabricated pneumatic walking brace (PPWB). Five plantar foot sensors (Interlink Electronics, Santa Barbara, CA) were placed at the first, third, and fifth metatarsal heads, fifth metatarsal base, and midplantar heel of 10 healthy male subjects. Each subject walked at a constant speed over a distance of 280 meters in a SS, PPWB, and TCC. A custom-made portable microprocessor-based system, with demonstrated accuracy and reliability, was used to acquire the data. No significant differences in peak pressure or contact duration were found between the initial and repeat SS trials (P > 0.05). Peak pressures were reduced in the PPWB as compared to the SS for all sensor locations (P < 0.05). Similarly, peak pressures were reduced in the TCC compared to the SS for all sensor locations (P < 0.05) with the exception of the fifth metatarsal base (P = 0.45). Our results are summarized as follows: (1) the methods used in the current study were found to be reliable through a test-retest analysis; (2) the PPWB decreased peak plantar foot pressures to an equal or greater degree than the TCC in all tested locations of the forefoot, midfoot, and hindfoot; (3) compared to a SS, contact durations were increased in both the TCC and PPWB for most sensor locations; and (4) the relationship of peak pressure over time, the pressure-time integral, is lower in the brace compared to the shoe at the majority of sensor locations. The values are not significantly different between the cast and shoe. These findings suggest an unweighting of the plantar foot and equalization of plantar foot pressures with both the PPWB and TCC. Based on these findings, the PPWB may be useful in the treatment of neuropathic plantar ulcerations of the foot.Keywords
This publication has 31 references indexed in Scilit:
- Sensate and insensate in-shoe plantar pressuresArchives of Physical Medicine and Rehabilitation, 1993
- The Patellar Tendon-Bearing Brace as Treatment for Neurotrophic Arthropathy: A Dynamic Force Monitoring StudyFoot & Ankle, 1992
- The Assessment of Dynamic Foot-to-Ground Contact Forces and Plantar Pressure Distribution: A Review of the Evolution of Current Techniques and Clinical ApplicationsFoot & Ankle, 1990
- A Quantitative Assessment of the Effect of Metatarsal Pads on Plantar PressuresFoot & Ankle, 1990
- Shoes for the Insensitive Foot: The Effect of a “Rocker Bottom” Shoe Modification on Plantar Pressure DistributionFoot & Ankle, 1990
- Measurement of discrete vertical in-shoe stress with piezoelectric transducersJournal of Biomedical Engineering, 1988
- A Clinician's View of Foot Pressure: A Comparison of Three Different Methods of MeasurementFoot & Ankle, 1987
- Foot pressure patterns during gaitJournal of Biomedical Engineering, 1985
- The Effect of Immobilization Devices on the Load Distribution Under the FootPublished by Wolters Kluwer Health ,1985
- Reduction of Abnormal Foot Pressures in Diabetic Neuropathy Using a New Polymer Insole MaterialDiabetes Care, 1984