Measurement of formaldehyde concentrations in a subatmospheric steam-formaldehyde autoclave.
Open Access
- 1 June 1979
- journal article
- research article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 32 (6) , 567-575
- https://doi.org/10.1136/jcp.32.6.567
Abstract
A method has been developed for measuring formaldehyde concentrations in a subatmospheric steam-formaldehyde autoclave. Data obtained using this method indicate that the concentration of formaldehyde in the chamber atmosphere is not homogeneous and that it decreases rapidly with time. The penetration of formaldehyde vapour into narrow tubes has also been investigated and was shown to be dependent on the length-to-bore ratio of the tubes. The formaldehyde concentration within the tubes could be increased by using a lower vacuum in the air removal stage at the beginning of the cycle.This publication has 7 references indexed in Scilit:
- Processing urinary endoscopes in a low-temperature steam and formaldehyde autoclave.Journal of Clinical Pathology, 1977
- DISINFECTION OF CYSTOSCOPES BY LOW-TEMPERATURE STEAMThe Lancet, 1977
- DISINFECTION OF CYSTOSCOPES BY LOW-TEMPERATURE STEAMThe Lancet, 1977
- Sterilization by means of ethylene oxide.1975
- The air desplacement process in industrial ethylene oxide sterilization.1970
- Sterilization with gaseous ethylene oxide: A review of chemical and physical factorsBiotechnology & Bioengineering, 1967
- Use of Gaseous Antimicrobial Agents with Special Reference to Ethylene OxideJournal of Applied Bacteriology, 1967