Coronary flow reserve: measurement with transthoracic Doppler echocardiography is reproducible and comparable with positron emission tomography
- 1 January 2001
- journal article
- clinical trial
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 21 (1) , 114-122
- https://doi.org/10.1046/j.1365-2281.2001.00296.x
Abstract
Detection of early vascular changes indicated by lowered coronary flow reserve (CFR) would allow early treatment and prevention of atherosclerosis. The purpose of this study was to test whether it is possible to reproducibly measure CFR with transthoracic Doppler echocardiography (TTE) in healthy volunteers. We measured CFR using dipyridamole infusion in ten healthy male volunteers with two methods: TTE and positron emission tomography (PET) with oxygen‐15‐labelled water (group A). However, CFR was assessed twice with TTE in eight healthy male volunteers (group B) to study the reproducibility of this method. We compared CFRs obtained using TTE flow measurements in the left anterior descending coronary artery (LAD) and PET flow measurements in the corresponding myocardial area. Coronary flow in LAD could be measured in all subjects using TTE. By TTE, an average CFR based on peak diastolic flow velocity (PDV) was 2·72 ± 1·16, mean diastolic flow velocity (MDV) 2·56 ± 1·06 and velocity time integral (VTI) 1·87 ± 0·49. The results were reproducible in two repeated TTE studies (coefficient of variation in MDV 6·1 ± 4·3%,n=8). By PET, CFR was 2·52 ± 0·84. CFR assessed by TTE correlated closely with that measured by PET (MDVr=0·942,Pr=0·912,Pr=0·888,P<0·006) and intraclass correlation was 0·929 (MDV) and tolerance limits for differences of CFRs was −0·78 to 0·72. We show that CFR measured by TTE has an excellent correlation with CFR measured by PET. We also found that TTE measurements of CFR were highly reproducible.Keywords
This publication has 32 references indexed in Scilit:
- Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiographyJournal of the American College of Cardiology, 1998
- Coronary Flow Reserve Is Impaired in Young Men With Familial HypercholesterolemiaJournal of the American College of Cardiology, 1996
- Intracoronary doppler guide wire versus stress single-photon emission computed tomographic thallium-201 imaging in assessment of intermediate coronary stenosisJournal of the American College of Cardiology, 1994
- Relation between Myocardial Blood Flow and the Severity of Coronary-Artery StenosisNew England Journal of Medicine, 1994
- Altered coronary vasodilator reserve and metabolism in myocardium subtended by normal arteries in patients with coronary artery diseaseJournal of the American College of Cardiology, 1993
- Assessing the hemodynamic significance of coronary artery stenosis: Analysis of translesional pressure-flow velocity relations in patientsJournal of the American College of Cardiology, 1993
- Estimation of coronary flow reserve by intracoronary doppler flow probes and digital angiographyCatheterization and Cardiovascular Diagnosis, 1990
- Noninvasive measurement of coronary artery blood flow using combined two-dimensional and Doppler echocardiographyJournal of the American College of Cardiology, 1987
- Methods of measurement of myocardial blood flow in patients: a critical review.Circulation, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986