Analysis of Organoselenium Compounds in Human Urine Using Active Carbon and Chemically Modified Silica Sol−Gel Surface-Assisted Laser Desorption/Ionization High-Resolution Time-of-Flight Mass Spectrometry
- 4 March 2004
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (7) , 2062-2070
- https://doi.org/10.1021/ac020707z
Abstract
Laser desorption/ionization time-of-flight mass spectra of three thermally labile low molecular weight organoselenium compounds (selenomethionine, selenoethionine, trimethylselenonium iodide) in human urine matrix have been obtained by using surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS). Four active layers, active carbon, silica sol−gel, and silica sol−gel impregnated with crown ether and with active carbon, were deposited on three different support substrates: (i) microscope slide coverslips; (ii) Al foil; and (iii) Cu tapes. Primarily protonated molecular ions and alkali metal adducts were observed in the mass spectra. A mixed-silica sol−gel and active carbon substrate active layer gave the best signal response for all compounds. Sol−gel substrates offered very clean backgrounds compared to the pure active carbon layers; however, the mass spectral signal intensities acquired were substantially lower for the sol−gel surfaces than those of the pure active carbon under the same conditions. Cu tape and Al foil support materials gave strong mass spectra of molecular ions and alkali metal molecular ion adducts, with lower Na and K adducts found with the Cu tape than with Al foil. Glass coverslips gave no response under all experimental conditions examined. Aerosol deposition was used to prepare SALDI substrates to avoid the localized “sweet spot” phenomenon encountered in conventional SALDI substrate preparation. Various nebulizers were examined and found to be effective in producing SALDI films with controlled and reproducible thicknesses. We were able to obtain exact mass identification of all three selenium species by high-resolution TOF-MS. To the best of our knowledge, this is the first time low molecular weight organoselenium compounds have been identified by SALDI-high-resolution TOF-MS.Keywords
This publication has 27 references indexed in Scilit:
- Desorption−Ionization Mass Spectrometry Using Deposited Nanostructured Silicon FilmsAnalytical Chemistry, 2001
- Stability and Storage Problems in Selenium Speciation from Environmental SamplesInternational Journal of Environmental Analytical Chemistry, 1999
- Graphite/Liquid Mixed Matrices for Laser Desorption/Ionization Mass SpectrometryAnalytical Chemistry, 1996
- Graphite surface-assisted laser desorption/ionization time-of-flight mass spectrometry of peptides and proteins from liquid solutionsAnalytical Chemistry, 1995
- Sample exposure effects in matrix-assisted laser desorption—ionization mass spectrometry of large biomoleculesInternational Journal of Mass Spectrometry and Ion Processes, 1994
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988
- Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 1988
- Aging and drying of gelsJournal of Non-Crystalline Solids, 1988
- Drying gelsJournal of Non-Crystalline Solids, 1986
- Analysis of selenium at the ultra-trace level by gas chromatographyJournal of Chromatography A, 1984