Imaging and Sizing of Atrial Septal Defects by Magnetic Resonance
- 15 December 1995
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 92 (12) , 3473-3480
- https://doi.org/10.1161/01.cir.92.12.3473
Abstract
Background Development of techniques for percutaneous closure of atrial septal defects (ASDs) makes accurate noninvasive sizing of ASDs important for appropriate patient selection. Methods and Results Magnetic resonance (MR) images of ASDs were obtained in 30 patients (mean age, 41±16 years) by both spin-echo and phase-contrast cine MR imaging. Spin-echo images were obtained in two orthogonal views (short-axis and four-chamber) perpendicular to the plane of the ASD. Spin-echo major and minor diameters were measured, and spin-echo defect area was calculated. Phase-contrast cine MR images were obtained in the plane of the ASD, and cine major diameter and defect area were measured from the region of signal enhancement or phase change due to shunt flow across the defect. MR measurements were compared with templates cut during surgery to match the defect or with ASD diameter determined by balloon sizing at catheterization. ASD size measured from cine MR images (y) agreed closely with catheterization and template standards (x). For major diameter, y=0.78x+5.7, r=.93, and SEE=3.4 mm. On average, spin-echo measurements overestimated major diameter and area of secundum ASDs by 48% and 125%, respectively. Conclusions Phase-contrast cine MR images acquired in the plane of an ASD define the defect shape by the cross section of the shunt flow stream and allow noninvasive determination of defect size with sufficient accuracy to permit stratification of patients to closure of the defect by catheter-based techniques versus surgery. Spin-echo images, on the other hand, are not adequate for defining ASD size, because septal thinning adjacent to a secundum ASD may appear to be part of the defect.Keywords
This publication has 17 references indexed in Scilit:
- Atrial septal defect occlusion with the buttoned device (a multi-institutional U.S. trial)The American Journal of Cardiology, 1994
- Three-dimentional ultrasound imaging of the atrial septum: Normal and pathologic anatomyJournal of the American College of Cardiology, 1993
- Selective presaturation magnetic resonance angiography: New method for detecting intracardiac shuntsAmerican Heart Journal, 1993
- Quantification of left to right atrial shunts with velocity-encoded cine nuclear magnetic resonance imagingJournal of the American College of Cardiology, 1992
- Echocardiographic estimation of balloon-stretched diameter of secundum atrial septal defect for transcatheter occlusionAmerican Heart Journal, 1992
- Uses and limitations of transthoracic echocardiography in the assessment of atrial septal defect in the adultThe American Journal of Cardiology, 1991
- Diagnosis and quantitative evaluation of secundum-type atrial septal defect by transesophageal Doppler echocardiographyThe American Journal of Cardiology, 1990
- Usefulness of anatomic parameters derived from two‐dimensional echocardiography for estimating magnitude of left to right shunt in patients with atrial septal defectClinical Cardiology, 1987
- Magnetic resonance velocity mapping: clinical application of a new technique.Heart, 1987
- Detection of ostium secundum atrial septal defects by transoesophageal cross-sectional echocardiography.Heart, 1983