Computer-assisted glucose control in critically ill patients
Open Access
- 4 April 2008
- journal article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 34 (8) , 1421-1427
- https://doi.org/10.1007/s00134-008-1091-y
Abstract
Intensive insulin therapy is associated with the risk of hypoglycemia and increased costs of material and personnel. We therefore evaluated the safety and efficiency of a computer-assisted glucose control protocol in a large population of critically ill patients. Observational cohort study in three intensive care units (32 beds) in a 1,300-bed university teaching hospital. All 2,800 patients admitted to the surgical, neurosurgical, and cardiothoracic units; the study period started at each ICU after implementation of Glucose Regulation for Intensive Care Patients (GRIP), a freely available computer-assisted glucose control protocol. We analysed compliance in relation to recommended insulin pump rates and glucose measurement frequency. Patients were on GRIP-ordered pump rates 97% of time. Median measurement time was 5 min late (IQR 20 min early to 34 min late). Hypoglycemia was uncommon (7% of patients for mild hypoglycemia, < 3.5 mmol/l; 0.86% for severe hypoglycemia, < 2.2 mmol/l). Our predefined target range (4.0–7.5 mmol/l) was reached after a median of 5.6 h (IQR 0.2–11.8) and maintained for 89% (70–100%) of the remaining stay at the ICU. The number of measurements needed was 5.9 (4.8–7.3) per patient per day. In-hospital mortality was 10.1%. Our computer-assisted glucose control protocol provides safe and efficient glucose regulation in routine intensive care practice. A low rate of hypoglycemic episodes was achieved with a considerably lower number of glucose measurements than used in most other schemes.Keywords
This publication has 31 references indexed in Scilit:
- Tight glycaemic control: a prospective observational study of a computerised decision-supported intensive insulin therapy protocolCritical Care, 2007
- Fatal neuroglycopaenia after accidental use of a glucose 5% solution in a peripheral arterial cannula flush systemAnaesthesia, 2007
- Computer-based Insulin Infusion Protocol Improves Glycemia Control over Manual ProtocolJournal of the American Medical Informatics Association, 2007
- Current controversies around tight glucose control in critically ill patientsCurrent Opinion in Clinical Nutrition and Metabolic Care, 2007
- Intensive Insulin Therapy in the Medical ICUNew England Journal of Medicine, 2006
- Hypoglycemia and Cardiac Arrest in a Critically Ill Patient on Strict Glycemic ControlAnesthesia & Analgesia, 2006
- Glycemic Control in the Intensive Care Unit: Why We Should Wait for NICE-SUGARMayo Clinic Proceedings, 2005
- Effects of Computerized Clinical Decision Support Systems on Practitioner Performance and Patient OutcomesJAMA, 2005
- Use of a Computerized Guideline for Glucose Regulation in the Intensive Care Unit Improved Both Guideline Adherence and Glucose RegulationJournal of the American Medical Informatics Association, 2004
- Effect of an Intensive Glucose Management Protocol on the Mortality of Critically Ill Adult PatientsMayo Clinic Proceedings, 2004