Magnetic Resonance Angiography at 3.0 Tesla: Initial Clinical Experience
- 1 June 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Topics in Magnetic Resonance Imaging
- Vol. 12 (3) , 183-204
- https://doi.org/10.1097/00002142-200106000-00005
Abstract
Magnetic resonance (MR) angiography has undergone significant development over the past decade. It has gone from being a novelty application of MR with limited clinical use to replacing catheter angiography in some clinical applications. One of the principal limitations inherent to all MR angiographic techniques is that they remain signal limited when pushed to the limits of higher resolution and short acquisition time. Developments in magnetic gradient hardware, coil design, and pulse sequences now are well optimized for MR angiography obtained at 1.5-T main magnetic field (B-field) strength, with acquisition times and imaging matrix size near their optimal limits, respectively. Recently, the United States Food and Drug Administration (FDA) approved use of clinical magnetic resonance imaging with main magnetic field strengths of up to 4 T. Before FDA approval, use of MR with magnetic field strengths much greater than 1.5 T was essentially reserved for investigational or research applications. The main advantage of high B-field imaging is a significant improvement in the signal-to-noise ratio (SNR), which increases in an approximately linear fashion with field strength in the range of 1.5 to 3.0 T. This increased SNR is directly available when performing MR angiographic acquisitions at higher magnetic field strengths, allowing for better resolution and conspicuity of vessels with similar acquisition times. Little has been reported on the benefits of performing MR angiography at magnetic field strengths >1.5 T. The purpose of this article is to summarize our current experience with intracranial and cervical MR angiographic techniques at 3.0 T.Keywords
This publication has 13 references indexed in Scilit:
- Carotid Arteries: Maximizing Arterial to Venous Contrast in Fluoroscopically Triggered Contrast-enhanced MR Angiography with Elliptic Centric View OrderingRadiology, 1999
- Intracranial vascular stenosis and occlusion: comparison of 3D time-of-flight and 3D phase-contrast MR angiographyNeuroradiology, 1998
- The application of magnetization transfer to MR angiography with reduced total powerMagnetic Resonance in Medicine, 1995
- Intracranial MR angiography: comparison of single-volume three-dimensional time-of-flight and multiple overlapping thin slab acquisition techniques.American Journal of Roentgenology, 1994
- Optimizing three-dimensional time-of-flight MR angiography with variable repetition time.Radiology, 1994
- T2-weighted spin-echo pulse sequence with variable repetition and echo times for reduction of MR image acquisition time.Radiology, 1991
- MR angiography with two-dimensional acquisition and three-dimensional display. Work in progress.Radiology, 1989
- MR Angiography with Gradient Motion RefocusingJournal of Computer Assisted Tomography, 1988
- MR Flow Imaging by Velocity-Compensated/Uncompensated Difference ImagesJournal of Computer Assisted Tomography, 1987
- A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1–100 MHz: Dependence on tissue type, NMR frequency, temperature, species, excision, and ageMedical Physics, 1984