Multispiral three-dimensional computed tomography in the investigation of craniosynostosis: technique optimization
- 1 July 1995
- journal article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 68 (811) , 724-730
- https://doi.org/10.1259/0007-1285-68-811-724
Abstract
21 infants with craniosynostosis were studied with a new three-dimensional (3D) computed tomography (CT) methodology. We describe technique optimization using multiple spiral data acquisitions with low dose (85 mAs) technique. One caudal volume of 3 mm slice thickness was obtained with a further two volumes of 1 mm slice thickness at the vertex. Image reconstruction of spiral raw data allowed overlapping 3 mm sections to be generated without the dose increase that would result from conventional axial CT scanning. We illustrate common technical artefacts of 3D CT and explain their cause and solution. A dramatic dose reduction to the lens was achieved with no loss in 3D image quality. Lens dose was 8.91 mSv compared with 24.6 mSv using the standard paediatric head technique.Keywords
This publication has 4 references indexed in Scilit:
- Frequency of craniosynostosis in Yorkshire, UKThe Lancet, 1993
- The Subarachnoid Spaces in CraniosynostosisNeurosurgery, 1992
- Hydrocephalus in craniosynostosisChild's Nervous System, 1988
- Three-dimensional anatomical images from computed tomographic scansThe British Journal of Radiology, 1986