Detection, localization, and quantitation of bioprosthetic mitral valve regurgitation. An in vitro two-dimensional color-Doppler flow-mapping study.
- 1 September 1988
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 78 (3) , 529-538
- https://doi.org/10.1161/01.cir.78.3.529
Abstract
The usefulness of two-dimensional color-Doppler flow-imaging (2D Doppler) in the detection, localization, and quantitation of bioprosthetic mitral valve regurgitation is uncertain. Mitral bioprostheses, before and after the creation of transvalvular (n = 33), paravalvular (n = 17), or combined (n = 23) defects, were mounted in a pulsed duplication system (flow rates, 2.5-6.5 l/min; pulse rate, 70 beats/min). An Aloka 880 2D Doppler system (Japan) was used to image the regurgitant jets in the simulated left atrial chamber, analogous to images obtained with transesophageal echocardiography. Jet area was corrected to an estimate of stroke volume: 2D Doppler measurements were divided by [(valve effective orifice area) X (continuous-wave Doppler-determined mean diastolic filling velocity)]/pulse rate. Regurgitant fraction and regurgitant volume were measured by an electromagnetic flow probe. 2D Doppler correctly identified the presence and location of paravalvular regurgitation. In transvalvular and combined transvalvular-paravalvular defects, there were six incorrect interpretations, all having transvalvular regurgitant volumes less than 4 ml/beat. In the presence of transvalvular regurgitation, jet area, length, and width correlated linearly with regurgitant volume (r = 0.82, 0.80, and 0.68, respectively; p less than 0.0001) and regurgitant fraction (r = 0.62, 0.61, and 0.45, respectively; p less than 0.001). Correlations with regurgitant fraction were improved when 2D Doppler measurements were corrected for stroke volume (r = 0.78, 0.79, and 0.67, respectively; p less than 0.0001). Mitral bioprostheses with transvalvular defects were also studied at varying flow rates (3.2-7.5 l/min) and pulse rates (70, 90, and 110 beats/min). The correlation between jet area and regurgitant volume was improved with a second-order polynomial regression (r = 0.93, p less than 0.0001). Our conclusions are that 1) in this in vitro model analogous to transesophageal imaging, 2D Doppler accurately detects and localizes bioprosthetic mitral valve regurgitation; 2) in transvalvular bioprosthetic mitral valve regurgitation, 2D Doppler measurement of jet area has a curvilinear relation with regurgitant volume, and correlation with regurgitant fraction is improved with correction for stroke volume; and 3) in paravalvular bioprosthetic mitral valve regurgitation, correlations between 2D Doppler measurements and regurgitant volumes are weaker, possibly because of jet eccentricity.This publication has 26 references indexed in Scilit:
- Pulsed Doppler regurgitant flow patterns of normal valvesThe American Journal of Cardiology, 1986
- Doppler echocardiographic evaluation of Hancock and Björk-Shiley prosthetic valvesJournal of the American College of Cardiology, 1986
- Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and Bioprosthetic (Hancock and Carpentier-Edwards) cardiac valvesThe American Journal of Cardiology, 1985
- Limitations of qualitative angiographic grading in aortic or mitral regurgitationThe American Journal of Cardiology, 1984
- Echocardiographic evaluation of porcine bioprosthetic valves: Experience with 309 normal and 59 dysfunctioning valvesThe American Journal of Cardiology, 1983
- Regurgitation of prosthetic heart valves: Dependence on heart rate and cardiac outputThe American Journal of Cardiology, 1983
- Localisation and direction of mitral regurgitant flow in mitral orifice studied with combined use of ultrasonic pulsed Doppler technique and two dimensional echocardiography.Heart, 1982
- Assessment of pulsed Doppler echocardiography in detection and quantification of aortic and mitral regurgitation.Heart, 1980
- Two dimensional echocardiographic assessment of patients with bioprosthetic valvesThe American Journal of Cardiology, 1979
- Echocardiogram of the porcine aortic bioprosthesis in the mitral positionThe American Journal of Cardiology, 1976