Wear Debris in Total Joint Replacements
- 1 July 1994
- journal article
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 2 (4) , 212-220
- https://doi.org/10.5435/00124635-199407000-00004
Abstract
An adverse local host response leading to periprosthetic bone loss, which can compromise implant fixation and bone stock. The authors review the basic mechanisms of implant degradation and the host response to particulate degradation products, particularly in the context of the pathogenesis of osteolysis. Submicron polyethylene particles (mean size, 0.5 μm) are the dominant type of wear particle present in periprosthetic tissues associated with uncemented hip replacements. Polyethylene wear can be minimized by improving the quality of the polyethylene, avoiding use of large-diameter (greater than 28 mm) femoral heads in total hip arthroplasty, and improving the design and fabrication of modular connections, which can be important sources of threebody wear particles. Advances in the understanding of the basic mechanisms of osteolysis are critical to the development of preventive measures that will minimize the clinical impact of this phenomenon....Keywords
This publication has 20 references indexed in Scilit:
- Composition and morphology of wear debris in failed uncemented total hip replacementThe Journal of Bone and Joint Surgery. British volume, 1994
- In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy couplingJournal of Biomedical Materials Research, 1993
- Bone resorption activity of particulate-stimulated macrophagesJournal of Bone and Mineral Research, 1993
- Current Concepts in Orthopaedic Biomaterials and Implant FixationJournal of Bone and Joint Surgery, 1993
- The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles.Journal of Bone and Joint Surgery, 1993
- Production of cytokines around loosened cemented acetabular components. Analysis with immunohistochemical techniques and in situ hybridization.Journal of Bone and Joint Surgery, 1993
- Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement.Journal of Bone and Joint Surgery, 1993
- Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplastiesThe Journal of Bone and Joint Surgery. British volume, 1990
- Bone lysis in well-fixed cemented femoral componentsThe Journal of Bone and Joint Surgery. British volume, 1990
- Reactions of the articular capsule to wear products of artificial joint prosthesesJournal of Biomedical Materials Research, 1977