Iron-Oxide-Enhanced Magnetic Resonance Imaging of Atherosclerotic Plaques
- 1 July 2002
- journal article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 37 (7) , 405-411
- https://doi.org/10.1097/00004424-200207000-00008
Abstract
Contrast-enhanced magnetic resonance (MR) imaging using ultra small superparamagnetic iron oxide (USPIO) particles is a new noninvasive modality for imaging inflammatory atherosclerotic plaques. We determined the accuracy, interobserver agreement, and potential sources of error of this technique by means of postmortem MR imaging of aortic preparations. Anesthetized atherosclerotic Watanabe heritable hyperlipidemic (WHHL) rabbits were studied after administration of different dosages of intravenous USPIO (DDM 43/34, IDF Berlin, Germany) and different postcontrast time intervals. A (n = 5) received 0 μmol Fe/kg. B (n = 5) received 50 μmol Fe/kg, 8-hour postcontrast interval. C (n = 5) received 50 μmol, 24 hours. D received 200 μmol, 48 hours. The aortas were removed and 3-mm segments prepared for postmortem examination by MR imaging using a T2-weighted gradient-echo sequence (TR/TE/FA; 41 milliseconds/11 milliseconds/15°), radiography (mammography), and histology (iron staining). USPIO accumulation was defined as the presence of 20 iron-positive cells per microscopic view (×100 magnification). Two independent readers analyzed the MR images and rated their confidence level for a positive MRI finding, defined as a focal signal loss, on a 5-point scale. The results were evaluated by receiver-operator characteristic (ROC) analysis. Of a total of 621 vessel segments technically acceptable for evaluation, 534 were histologically negative and 87 positive. Accuracy, expressed as the area under the ROC curve, was 0.85 for reader 1 and 0.88 for reader 2. Interobserver agreement was 0.67. False-positive findings were established by at least one reader for 121 of the 621 segments, false-negative findings for only 15 segments. Calcifications and mural thrombi were identified as potential sources of error of the method. Postmortem USPIO-enhanced MR imaging of atherosclerotic plaques showed a high accuracy and good interobserver agreement in the animal model used here. Further optimization of the method should aim at reducing the rather high percentage of false-positive results.Keywords
This publication has 13 references indexed in Scilit:
- Magnetic resonance imaging of atherosclerotic plaques using superparamagnetic iron oxide particlesJournal of Magnetic Resonance Imaging, 2001
- Magnetic Resonance Imaging of Atherosclerotic Plaque With Ultrasmall Superparamagnetic Particles of Iron Oxide in Hyperlipidemic RabbitsCirculation, 2001
- Atherosclerosis — An Inflammatory DiseaseNew England Journal of Medicine, 1999
- In Vitro and In Situ Magnetic Resonance Imaging Signal Features of Atherosclerotic Plaque-Associated LipidsArteriosclerosis, Thrombosis, and Vascular Biology, 1997
- A Definition of Advanced Types of Atherosclerotic Lesions and a Histological Classification of AtherosclerosisArteriosclerosis, Thrombosis, and Vascular Biology, 1995
- Some Practical Issues of Experimental Design and Data Analysis in Radiological ROC StudiesInvestigative Radiology, 1989
- High‐resolution H NMR spectral signature from human atheromaMagnetic Resonance in Medicine, 1988
- ROC Methodology in Radiologic ImagingInvestigative Radiology, 1986
- ROC Analysis Applied to the Evaluation of Medical Imaging TechniquesInvestigative Radiology, 1979
- Basic principles of ROC analysisSeminars in Nuclear Medicine, 1978