Measurement of tumor vascular volume and mean microvascular random flow velocity magnitude by dynamic GD‐DTPA‐Albumin enhanced and diffusion‐weighted MRI
- 1 September 1998
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 40 (3) , 397-404
- https://doi.org/10.1002/mrm.1910400309
Abstract
Tumor vascular volume fraction and the magnitude of the mean microvascular random flow velocity were measured in an animal tumor model by combining dynamic Gd‐DTPA‐albumin enhanced MRI and diffusion‐weighted MRI in conjunction with a compartmental modeling analysis. The vascular volume fraction maps were obtained from the dynamic Gd‐DTPA‐albumin enhanced MRI measurement. It was found that the vascular volume fraction for Walker 256 tumor was higher within the outgrowing rim and decreased towards the central region. The average value obtained from five animals was 0.062 ± 0.009 ml/g. By using the vascular volume fraction from the Gd‐DTPA‐albumin enhanced MRI measurement, maps of the magnitude of the mean microvascular random flow velocity were obtained from the diffusion‐weighted MRI measurements with the compartmental modeling analysis. The relative extravascular and intravascular contributions to the diffusion‐weighted MRI signal were determined for three tissue groups with different Gd‐DTPA‐albumin enhancement characteristics, and the flow and molecular diffusion‐induced attenuation factors for the intravascular compartment were also compared. The mean microvascular random flow velocity magnitude maps were obtained with an average value of 0.67 ± 0.06 mm/s.Keywords
This publication has 36 references indexed in Scilit:
- Quantification of liver blood volume: comparison of ultra short ti inversion recovery echo planar imaging (ulstir‐epi), with dynamic 3d‐gradient recalled echo imagingMagnetic Resonance in Medicine, 1995
- Measurement of vascular volume fraction and blood‐tissue permeability constants with a pharmacokinetic model: Studies in rat muscle tumors with dynamic Gd‐DTPA enhanced MRIMagnetic Resonance in Medicine, 1994
- Statistical description of microcirculatory flow as measured with an MR methodJournal of Magnetic Resonance Imaging, 1993
- Measurement of capillary permeability to macromolecules by dynamic magnetic resonance imaging: A quantitative noninvasive techniqueMagnetic Resonance in Medicine, 1993
- Dynamic studies of gadolinium uptake in brain tumors using inversion‐recovery echo‐planar imagingMagnetic Resonance in Medicine, 1992
- Separation of diffusion and slow flow effects by use of flow rephasing and dephasingMagnetic Resonance in Medicine, 1992
- The use of gradient flow compensation to separate diffusion and microcirculatory flow in MRIMagnetic Resonance in Medicine, 1991
- Quantitative measurement of tissue perfusion and diffusion in vivoMagnetic Resonance in Medicine, 1991
- Attempts to increase intratumoral blood flow in the rat solid walker 256 tumor by the use of the perfluorocarbon emulsion fluosol-DAEuropean Journal of Cancer and Clinical Oncology, 1987
- The effects of random directional distributed flow in nuclear magnetic resonance imagingMedical Physics, 1987