Methods for fully automated verification of patient set-up in external beam radiotherapy with polygon shaped fields
- 1 June 1994
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 39 (6) , 993-1012
- https://doi.org/10.1088/0031-9155/39/6/006
Abstract
Methods have been developed to perform fully automated comparisons of the radiotherapy simulator and portal images in the most common cases where the field edges consist of straight lines. The field defining wires or rods in the simulator image, and the edges of the portal image, are localized by means of a truncated Radon transform. Edges are enhanced with the use of a generalized Laplacian operator. From the detected field outlines, a geometrical mapping function is determined that rotates, scales, and translates one image with respect to the other. A subsequent match of held shapes is executed. If satisfactory agreement is established, the anatomical structures of the simulator and portal images are compared by correlating a new pair of images that only contain the intensity ridges representing bone outlines. The correlation determines the rotation and translation that must be applied to align the anatomical structures. With the simulator image already processed, the remaining automatic processing takes approximately 2 min on a SUN Sparcstation 2. By use of a priori knowledge of the fields, the computation time needed after acquisition of the portal image may be reduced to about 40 s for 512*512 images and about 12 s for 256*256 images.Keywords
This publication has 15 references indexed in Scilit:
- Automatic on‐line inspection of patient setup in radiation therapy using digital portal imagesMedical Physics, 1993
- Three‐dimensional verification of patient placement during radiotherapy using portal imagesMedical Physics, 1993
- Automatic verification of radiation field shape using digital portal imagesMedical Physics, 1992
- Routine clinical on-line portal imaging followed by immediate field adjustment using a tele-controlled patient couchRadiotherapy and Oncology, 1992
- Use of the Radon transform as a method of extracting information about shape in two dimensionsImage and Vision Computing, 1992
- Radiation field edge detection in portal imagesPhysics in Medicine & Biology, 1991
- Fast evaluation of patient set-up during radiotherapy by aligning features in portal and simulator imagesPhysics in Medicine & Biology, 1991
- Study of treatment variation in the radiotherapy of head and neck tumors using a fiber-optic on-line radiotherapy imaging systemInternational Journal of Radiation Oncology*Biology*Physics, 1991
- Accuracy in radiation field alignment in head and neck cancer: A prospective studyRadiotherapy and Oncology, 1988
- Detection of Intensity Changes with Subpixel Accuracy Using Laplacian-Gaussian MasksIEEE Transactions on Pattern Analysis and Machine Intelligence, 1986