Abstract
A pilot study has been conducted in which coronary arteries subject to re-stenosis after angioplasty and stenting have been irradiated following further angioplasty. The method of irradiation has been to use radioactive188Re in an angioplasty balloon. This paper considers all aspects of the procedure including elution of the rhenium from a tungsten/rheniurn generator, its concentration, dispensing and safe delivery to the patient using specially designed equipment to reduce staff doses and radioactive spil1s. In the pilot study of 28 lesions in 26 patients only 1 was recorded as having angiographic re-stenosis in the treated region at 6 months although 4 other patients had edge re-stenosis. This represents less than 18% re-stenosis in a population that would have been expected to exhibit at least 50% re-stenosis at 6 months. A total of 72 patients have been treated either in the pilot study or a subsequent trial. In only one case has a minor spill of radioactivity occurred and in no case has the balloon burst. Radiation doses to staff are approximately 20 μSv per procedure and are therefore not of serious consequence. It is concluded that this procedure is safe, feasible and effective in reducing in-stent re-stenosis.Keywords
This publication has 16 references indexed in Scilit:
- Inhibition of Restenosis With β-Emitting RadiotherapyCirculation, 2000
- Intracoronary β-Irradiation With a Liquid 188 Re-Filled BalloonCirculation, 2000
- Three-Year Clinical and Angiographic Follow-Up After Intracoronary RadiationCirculation, 2000
- Pharmacokinetics of 99Tcm-pertechnetate and 188Re-perrhenate after oral administration of perchlorateNuclear Medicine Communications, 1998
- Intracoronary Low-Dose β-Irradiation Inhibits Neointima Formation After Coronary Artery Balloon Injury in the Swine Restenosis ModelCirculation, 1995
- Intra-arterial Beta Irradiation Prevents Neointimal Hyperplasia in a Hypercholesterolemic Rabbit Restenosis ModelCirculation, 1995
- Intracoronary Radiation Before Stent Implantation Inhibits Neointima Formation in Stented Porcine Coronary ArteriesCirculation, 1995
- Intracoronary irradiation markedly reduces neointimal proliferation after balloon angioplasty in swine: Persistent benefit at 6-month follow-upJournal of the American College of Cardiology, 1995
- Intracoronary irradiation markedly reduces restenosis after balloon angioplasty in a porcine modelJournal of the American College of Cardiology, 1994
- Nonoperative Dilatation of Coronary-Artery StenosisNew England Journal of Medicine, 1979