Refrigeration Requirements of the LN2 Cryo-Cable
- 1 November 1971
- journal article
- Published by ASME International in Journal of Engineering for Industry
- Vol. 93 (4) , 1161-1165
- https://doi.org/10.1115/1.3428056
Abstract
The paper considers the smallest size refrigeration plant likely to be required for liquid nitrogen cooled electric power transmission lines. Nitrogen, neon, hydrogen, and helium cycles are compared and it is shown that a neon cycle has considerable potential. An outline is given of a practical plant utilizing the nitrogen cycle and mainly rotating machinery, all based on present-day technology. The advantages which evaporative cooling confers on the operation of LN2 cryo-cables are explained.Keywords
This publication has 0 references indexed in Scilit: