MLM-based monochromator for molybdenum impurity monitoring on the Alcator C-MOD tokamak in the 30–130 Å range
- 1 October 1992
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 63 (10) , 5176-5178
- https://doi.org/10.1063/1.1143473
Abstract
Molybdenum, from the vessel wall armor tiles and divertor plates, is expected to be the dominant high‐Z impurity in the Alcator C‐MOD tokamak plasma. To monitor the molybdenum emission in the extreme ultraviolet (XUV), a monochromator utilizing multilayer mirrors (MLMs) as dispersive elements will be installed on the C‐MOD tokamak with a 10° above the mid‐plane view across the plasma’s center. Much of the strong Mo emission under the C‐MOD experimental conditions will be emitted between 30–50 Å and 65–90 Å by M‐shell ions (n=3–3 and n=3–4 transitions), at 116 Å from MoXXXI and at 127 Å from MoXXXII. The monochromator will have three MLMs and either three‐channel electron multipliers or three XUV silicon photodiodes mounted on a single θ‐2θ goniometer. Each MLM and detector unit will simultaneously monitor a separate molybdenum emission range with a 1–10‐ms temporal resolution. The resolution of the MLMs range from 1 to 5 Å depending on the wavelength, and each MLM will be optimized for one of the above spectral regions. This low‐resolution monitoring of many charge states will enable radiative power loss estimates and can be used in impurity transport analysis. The design of the monochromator and the expected Mo emission will be presented and discussed.Keywords
This publication has 8 references indexed in Scilit:
- Layered synthetic microstructures for soft x-ray spectroscopy of magnetically confined plasmas (invited)Review of Scientific Instruments, 1990
- Peak reflectivity measurements of W/C, Mo/Si, and Mo/B_4C multilayer mirrors in the 8–190-Å range using both Kα line and synchrotron radiationApplied Optics, 1990
- Energy Levels of Molybdenum, Mo I through Mo XLIIJournal of Physical and Chemical Reference Data, 1988
- Spectra of highly ionised zirconium and molybdenum in the 60-150 AA range from PLT tokamak plasmasJournal of Physics B: Atomic and Molecular Physics, 1985
- Molybdenum-silicon multilayer mirrors for the extreme ultravioletApplied Optics, 1985
- Low-energy x-ray interaction coefficients: Photoabsorption, scattering, and reflectionAtomic Data and Nuclear Data Tables, 1982
- The XUV spectra of highly ionised molybdenumJournal of Physics B: Atomic and Molecular Physics, 1978
- Identification of Mo XV to Mo XXXIII in the soft X-ray spectrum of the TFR TokamakPhysics Letters A, 1977