Steady‐state free precession with myocardial tagging: CSPAMM in a single breathhold
- 18 March 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 49 (4) , 722-730
- https://doi.org/10.1002/mrm.10422
Abstract
A method is presented that combines steady‐state free precession (SSFP) cine imaging with myocardial tagging. Before the tagging preparation at each ECG‐R wave, the steady‐state magnetization is stored as longitudinal magnetization by an α/2 flip‐back pulse. Imaging is continued immediately after tagging preparation, using linearly increasing startup angles (LISA) with a rampup over 10 pulses. Interleaved segmented k‐space ordering is used to prevent artifacts from the increasing signal during the LISA rampup. First, this LISA‐SSFP method was evaluated regarding ghost artifacts from the steady‐state interruption by comparing LISA with an α/2 startup method. Next, LISA‐SSFP was compared with spoiled gradient echo (SGRE) imaging, regarding tag contrast‐to‐noise ratio and tag persistence. The measurements were performed in phantoms and in six subjects applying breathhold cine imaging with tagging (temporal resolution 51 ms). The results show that ghost artifacts are negligible for the LISA method. Compared to the SGRE reference, LISA‐SSFP was two times faster, with a slightly better tag contrast‐to‐noise. Additionally, the tags persisted 126 ms longer with LISA‐SSFP than with SGRE imaging. The high efficiency of LISA‐SSFP enables the acquisition of complementary tagged (CSPAMM) images in a single breathhold. Magn Reson Med 49:722–730, 2003.Keywords
This publication has 14 references indexed in Scilit:
- Improved harmonic phase myocardial strain mapsMagnetic Resonance in Medicine, 2001
- 3D magnetization‐prepared true‐FISP: A new technique for imaging coronary arteriesMagnetic Resonance in Medicine, 2001
- Characterization and reduction of the transient response in steady‐state MR imagingMagnetic Resonance in Medicine, 2001
- Magnetization preparation during the steady state: Fat‐saturated 3D TrueFISPMagnetic Resonance in Medicine, 2001
- Direct calculation of 2D components of myocardial strain using sinusoidal MR taggingPublished by SPIE-Intl Soc Optical Eng ,1998
- Improved myocardial tagging contrastMagnetic Resonance in Medicine, 1993
- Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence.Radiology, 1991
- Retrospective cardiac gating: A review of technical aspects and future directionsMagnetic Resonance Imaging, 1989
- MR imaging of motion with spatial modulation of magnetization.Radiology, 1989
- Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.Radiology, 1988