Whole‐brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coil
Open Access
- 28 June 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (1) , 131-140
- https://doi.org/10.1002/mrm.20124
Abstract
A variety of continuous and pulsed arterial spin labeling (ASL) perfusion MRI techniques have been demonstrated in recent years. One of the reasons these methods are still not routinely used is the limited extent of the imaging region. Of the ASL methods proposed to date, continuous ASL (CASL) with a separate labeling coil is particularly attractive for whole-brain studies at high fields. This approach can provide an increased signal-to-noise ratio (SNR) in perfusion images because there are no magnetization transfer (MT) effects, and lessen concerns regarding RF power deposition at high field because it uses a local labeling coil. In this work, we demonstrate CASL whole-brain quantitative perfusion imaging at 3.0 T using a combination of strategies: 3D volume acquisition, background tissue signal suppression, and a separate labeling coil. The results show that this approach can be used to acquire perfusion images in all brain regions with good sensitivity. Further, it is shown that the method can be performed safely on humans without exceeding the current RF power deposition limits. The current method can be extended to higher fields, and further improved by the use of multiple receiver coils and parallel imaging techniques to reduce scan time or provide increased resolution. Magn Reson Med 52:131–140, 2004. Published 2004 Wiley-Liss, Inc.Keywords
This publication has 33 references indexed in Scilit:
- Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 TeslaMagnetic Resonance in Medicine, 2002
- Design of a SENSE‐optimized high‐sensitivity MRI receive coil for brain imagingMagnetic Resonance in Medicine, 2002
- Test‐retest reproducibility of quantitative CBF measurements using FAIR perfusion MRI and acetazolamide challengeMagnetic Resonance in Medicine, 2002
- Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging TechniquesJournal of Cerebral Blood Flow & Metabolism, 1999
- Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spins within the detection sliceMagnetic Resonance in Medicine, 1996
- NMR Measurement of Perfusion Using Arterial Spin Labeling Without Saturation of Macromolecular SpinsMagnetic Resonance in Medicine, 1995
- Multi‐Slice MRI of Rat Brain Perfusion During Amphetamine Stimulation Using Arterial Spin LabelingMagnetic Resonance in Medicine, 1995
- Perfusion imagingMagnetic Resonance in Medicine, 1992
- Projection angiograms of blood labeled by adiabatic fast passageMagnetic Resonance in Medicine, 1986
- What is the Correct Value for the Brain-Blood Partition Coefficient for Water?Journal of Cerebral Blood Flow & Metabolism, 1985