Visualizing tissue compliance with MR imaging
- 1 November 1995
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 5 (6) , 733-738
- https://doi.org/10.1002/jmri.1880050620
Abstract
We propose a method for visualizing the mechanical properties of tissue based on the use of periodic mechanical compression in conjunction with phase-contrast MR imaging. A specialized mechanical transducer was used to provide programmable compression pulses to the surface of compliant phantoms. These compression pulses were synchronized to a spin-echo sequence with motion-sensitizing gradients to generate phase information reflecting spin displacement throughout the phantom. This sequence was tested with two agarose gel phantoms. The first was a cylinder containing three parallel layers of varying compliance and the second was composed of a semirigid sphere suspended in a uniform layer of decreased elastic modulus. Images showed complex patterns of motion throughout the phantom, which correlated with expected motion behavior of the phantom structures. This indicates that the biomechanical properties of tissues may be elucidated through the use of motion-sensitized MR imaging and suggests that a form of image contrast relating to tissue elasticity may be feasible.Keywords
This publication has 12 references indexed in Scilit:
- A velocity correlation method for measuring vascular compliance using MR imagingJournal of Magnetic Resonance Imaging, 1995
- MR measurement of pulsatile pressure gradientsJournal of Magnetic Resonance Imaging, 1994
- Factors influencing the accuracy and precision of velocity‐encoded phase imagingMagnetic Resonance in Medicine, 1992
- Pulsatile brain movement and associated hydrodynamics studied by magnetic resonance phase imagingNeuroradiology, 1992
- Encoding strategies for three‐direction phase‐contrast MR imaging of flowJournal of Magnetic Resonance Imaging, 1991
- “Sonoelasticity” images derived from ultrasound signals in mechanically vibrated tissuesUltrasound in Medicine & Biology, 1990
- Microvascular permeability of normal and neoplastic tissuesMicrovascular Research, 1986
- Agarose as a tissue equivalent phantom material for NMR imagingMagnetic Resonance Imaging, 1986
- A flow velocity zeugmatographic interlace for NMR imaging in humansMagnetic Resonance Imaging, 1982
- The significance of the “tissue pressure” of normal testicular and of neoplastic (Brown‐Pearce carcinoma) tissue in the rabbitThe Journal of Pathology and Bacteriology, 1950