An Experimental Model for the Acute and Chronic Evaluation of Intra-aneurysmal Pressure
- 1 August 1997
- journal article
- research article
- Published by International Society of Endovascular Specialists in Journal of Endovascular Surgery
- Vol. 4 (3) , 290-297
- https://doi.org/10.1583/1074-6218(1997)004<0290:aemfta>2.0.co;2
Abstract
To develop an animal model for the acute and chronic monitoring of pressure within abdominal aortic aneurysms (AAAs) to be treated with endovascular grafts. A strain-gauge pressure transducer was placed within an AAA created from a prosthetic vascular graft. Prosthetic aneurysms were implanted into 17 canine infrarenal aortas. The intra-aneurysmal pressure was monitored and correlated with noninvasive forelimb sphygmomanometry for 2 weeks. After this time, an intravascular manometer catheter was passed into the aneurysm. Simultaneous pressure measurements were obtained using the implanted strain-gauge pressure transducer, the manometer catheter, and the forelimb sphygmomanometer. Angiography was performed to assess intraluminal morphology, aneurysm anastomoses, and adjoining aortic vessels. In addition, two control animals underwent intra-aneurysmal pressure monitoring after standard surgical aneurysm repair. There was excellent correlation (r = 0.97) between the pressure measurements obtained with the implanted strain-gauge pressure transducer and the intravascular manometer. Close correlation was also observed between the implanted strain-gauge transducer and the forelimb sphygmomanometer (r = 0.88) during postprocedural monitoring. Intra-aneurysmal pressure was lowered dramatically by surgical exclusion (aneurysm: 15/5 +/- 7/4 mmHg; systemic: 124/66 +/- 34/17 mmHg; p < 0.001). The prosthetic aneurysms were successfully imaged with angiography. This animal model provides an accurate and reproducible means for measuring intra-aneurysmal pressure on an acute and chronic basis. It may be possible to use this model in the assessment of endovascular devices to determine their efficacy in reducing intra-aneurysmal pressure. Evaluation of complications associated with their use, such as patent aneurysm side branches, perigraft channels, and perianastomotic reflux, may also be possible.Keywords
This publication has 23 references indexed in Scilit:
- Aneurysm pressure following endovascular exclusionEuropean Journal of Vascular and Endovascular Surgery, 1997
- Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repairJournal of Vascular Surgery, 1996
- Initial Experience with Transluminally Placed Endovascular Grafts for the Treatment of Complex Vascular LesionsAnnals of Surgery, 1995
- An aortic aneurysm model for the evaluation of endovascular exclusion prosthesesJournal of Vascular Surgery, 1995
- Delayed rupture of aortic aneurysms following endovascular stent graftingThe American Journal of Surgery, 1995
- Transfemoral insertion of a bifurcated endovascular graft for aortic aneurysm repair: the first 22 patientsCardiovascular Surgery, 1995
- Transfemoral Repair of Abdominal Aortic AneurysmNew England Journal of Medicine, 1994
- Repair of Abdominal Aortic Aneurysm by Transfemoral Endovascular Graft PlacementAnnals of Surgery, 1994
- Healing of polytetrafluoroethylene arterial grafts is influenced by graft porosityJournal of Vascular Surgery, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986